Desa LMFP33PR BUILT-IN Fireplace Installation, Actual Framing Height 32 3 Front Width Depth

Page 10

10

INSTALLATION

Built-In Fireplace Installation

INSTALLATION

Continued

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

 

 

Framing

 

 

 

 

 

Height

32 3/8"

 

 

33"

Front Width

34

5/

16

"

 

35

1/ "

 

 

 

 

 

 

2

Depth

16

11/

16

"

17

3/ "

 

 

 

 

 

 

4

1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough opening.If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.

2.If using blower, install and properly ground GA3555, three- prong 120 volt electrical outlet, in fireplace. Follow instruc- tions included in kit (see Accessories, page 30).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Plug electrical cord into electrical outlet installed in step 2.

6.Carefully insert fireplace into rough opening.

7.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

9.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.

10.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

39 3/8"

27 7/8"

35 1/2" 55 5/8"

Figure 14 - Rough Opening for Installing in Corner

Nails or

Wood

Screws

Nailing Flanges

Figure 15 - Attaching Fireplace to Wall Studs

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

 

 

Framing

 

 

 

 

 

Height

32 3/8"

 

 

33"

Front Width

34

5/

16

"

 

35

1/ "

 

 

 

 

 

 

2

Depth

16

11/

16

"

17

3/ "

 

 

 

 

 

 

4

17 3/4"

33"

35 1/2"

Figure 13 - Rough Opening for Installing in Wall

WARNING: A qualified electrician must connect electrical wiring to duplex outlet for built-in installa- tion. Follow all local codes.

For..com

111604-01B

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLog Base Assembly Product IdentificationUnpacking Product FeaturesLocal Codes AIR for Combustion and VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupIncluded with Mantel Accessory Installation ClearancesAssembling and Attaching Optional Brass Trim Conventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Actual Framing Height 32 3 Front Width DepthSupport Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Check all other internal joints for leaksInstalling Logs Installing Logs 1Installing Battery into Remote For Your Safety Read Before LightingInstalling Batteries in Receiver Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litHAND-HELD Remote Operation Burner Primary AIR Holes Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Technical Service Wiring DiagramSpecifications Service HintsIllustrated Parts Breakdown Models LMFP33PRParts List KEY Part Number LMFP33PR LMFP33NR Description QTYFirebox LMFP33PR LMFP33NR Firebox LMFP33PR and LMFP33NR KEY Part Number Description QTYEquipment Shutoff Valve GA5010 AccessoriesBlower Accessory GA3750A GA3700TA Series Information VideoOwners Registration Form Postage Required 111604-01B Warranty Information

LMFP33PR specifications

Desa LMFP33PR is an advanced multipurpose electronic system that has gained attention for its impressive range of features and robust performance. Designed to cater to both commercial and residential applications, this device brings a blend of efficiency, flexibility, and user-friendliness to various tasks.

One of the standout features of the Desa LMFP33PR is its high power output, making it suitable for demanding applications. With a maximum wattage capacity that outstrips many competitors in its category, this device can handle significant loads, making it an ideal choice for businesses that require reliable energy sources. Its ability to support multiple devices simultaneously ensures that users can optimize productivity without compromising on performance.

In terms of technology, the Desa LMFP33PR incorporates innovative energy management systems. The integrated smart technology allows users to monitor energy consumption in real-time, offering insights into usage patterns. This can lead to informed decisions regarding energy use, ultimately resulting in cost savings and operational efficiency. Furthermore, the device is equipped with advanced safety features, including overload protection and surge suppression, which safeguards both the unit and connected devices.

The build quality of the Desa LMFP33PR is another aspect worth highlighting. Constructed from durable materials, it is designed to withstand the rigors of frequent use, making it ideal for environments where reliability is paramount. The compact design ensures that it can fit into various spaces without occupying too much physical room, a feature especially appreciated in busy work settings.

User experience is enhanced by an intuitive interface that simplifies operation. The inclusion of programmable settings allows users to customize its functionality according to their specific needs, adding a layer of convenience. Additionally, the Desa LMFP33PR is designed to be energy-efficient, aligning with the growing demand for sustainable solutions. By minimizing energy waste, this device contributes to environmentally friendly operations.

Finally, with customer support and service options readily available, users can access assistance whenever needed, ensuring a seamless experience throughout the lifecycle of the product. In conclusion, the Desa LMFP33PR stands out as a versatile and efficient solution for anyone in need of reliable electric management systems, combining power, durability, and smart technology in one package.