Desa LMFP33PR installation manual Support Bracket Firebox Wrapper Shield Power Screws Cord

Page 11

INSTALLATION

Built-In Fireplace Installation (Cont.)

11

INSTALLATION

Continued

1.Frame in rough opening. Use dimensions shown in Figure 16 for the rough opening.

2.If using blower, install wiring and properly ground the three- prong, 120 volt electrical outlet in fireplace.

3.Before replacing bottom of firebox, install duplex outlet to the right support bracket in the bottom of firebox (see Figure 17).

4.Route wires from electrical box through smallest hole in outer casing using strain relief fitting provided (see Figure 17).

5.Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to con- nect ground wire.

6.Install shield to end of right support bracket and behind the firebox wrapper with 2 screws provided (see Figure 18).

7.Plug blower cord into duplex outlet. Note: On thermostat model fireplaces, route power cord to the back of the fireplace to clear thermostat valve.

8.Replace bottom of firebox and reconnect remote receiver mod- ule to valve.

9.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

10.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

11.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.

12.Plug electrical cord into electrical outlet installed in step 2.

13.Carefully insert fireplace into rough opening.

14.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 19).

15.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.

16.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

17 3/4"

33"

 

Cable from

 

Electrical

 

Source

Blower

Duplex

 

Outlet

Blower

Strain

Power

Cord

Relief

 

Fitting

 

Support

 

Bracket

 

Screw

Figure 17 - Connecting Duplex Outlet

Support Bracket

Firebox

Wrapper

Shield

Power Screws

Cord

Figure 18 - Attaching Fireplace to Wall Studs

Nails or

Wood

Screws

Nailing Flanges

35 1/2"

 

Figure 19 - Attaching Fireplace to Wall Studs

 

Figure 16 - Rough Opening for Installing in Wall

For morevisit www..com

111604-01B

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base AssemblyAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesIncluded with Mantel Accessory Installing Cabinet Mantel Conventional Fireplace InstallationActual Framing Height 32 3 Front Width Depth BUILT-IN Fireplace InstallationSupport Bracket Firebox Wrapper Shield Power Screws Cord Installation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemCheck all other internal joints for leaks Pressure Testing Fireplace Gas ConnectionsInstalling Logs 1 Installing LogsOperating Heater For Your Safety Read Before LightingInstalling Batteries in Receiver Installing Battery into RemoteShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterHAND-HELD Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Service Hints Wiring DiagramSpecifications Technical ServiceModels LMFP33PR Illustrated Parts BreakdownKEY Part Number LMFP33PR LMFP33NR Description QTY Parts ListFirebox LMFP33PR LMFP33NR KEY Part Number Description QTY Firebox LMFP33PR and LMFP33NRInformation Video AccessoriesBlower Accessory GA3750A GA3700TA Series Equipment Shutoff Valve GA5010Owners Registration Form Postage Required 111604-01B Warranty Information

LMFP33PR specifications

Desa LMFP33PR is an advanced multipurpose electronic system that has gained attention for its impressive range of features and robust performance. Designed to cater to both commercial and residential applications, this device brings a blend of efficiency, flexibility, and user-friendliness to various tasks.

One of the standout features of the Desa LMFP33PR is its high power output, making it suitable for demanding applications. With a maximum wattage capacity that outstrips many competitors in its category, this device can handle significant loads, making it an ideal choice for businesses that require reliable energy sources. Its ability to support multiple devices simultaneously ensures that users can optimize productivity without compromising on performance.

In terms of technology, the Desa LMFP33PR incorporates innovative energy management systems. The integrated smart technology allows users to monitor energy consumption in real-time, offering insights into usage patterns. This can lead to informed decisions regarding energy use, ultimately resulting in cost savings and operational efficiency. Furthermore, the device is equipped with advanced safety features, including overload protection and surge suppression, which safeguards both the unit and connected devices.

The build quality of the Desa LMFP33PR is another aspect worth highlighting. Constructed from durable materials, it is designed to withstand the rigors of frequent use, making it ideal for environments where reliability is paramount. The compact design ensures that it can fit into various spaces without occupying too much physical room, a feature especially appreciated in busy work settings.

User experience is enhanced by an intuitive interface that simplifies operation. The inclusion of programmable settings allows users to customize its functionality according to their specific needs, adding a layer of convenience. Additionally, the Desa LMFP33PR is designed to be energy-efficient, aligning with the growing demand for sustainable solutions. By minimizing energy waste, this device contributes to environmentally friendly operations.

Finally, with customer support and service options readily available, users can access assistance whenever needed, ensuring a seamless experience throughout the lifecycle of the product. In conclusion, the Desa LMFP33PR stands out as a versatile and efficient solution for anyone in need of reliable electric management systems, combining power, durability, and smart technology in one package.