Desa LMFP33PR installation manual Connecting Fireplace to GAS Supply, Gas Connection

Page 13

INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace to Gas Supply

13

INSTALLATION

Continued

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

External

Propane/LP

Supply Tank

Regulator

 

Vent

Pointing

Down

Figure 21 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down

CSA Design-Certified Equipment

Shutoff Valve With 1/8" NPT Tap*

Natural Gas From Gas Meter

(5" W.C.** to 10.5" W.C. Pressure)

3" Minimum

Propane/LP

From External Regulator

 

 

(11" W.C.** to 14" W.C.

 

Pressure)

Cap Pipe

Tee

Nipple

Joint

Sediment Trap

Figure 22 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 30.

**Minimum inlet pressure for purpose of input adjustment.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 22. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove two screws that hold fireplace screen in place for ship- ping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Open lower louver door. Carefully pull straight out on the wire harnesses attached to right side and front of remote receiver module (see Figure 23, page 14).

3.Remove screws that attach log base assembly to fireplace (see Figure 23, page 14). Carefully lift up log base assembly and remove from fireplace (see Figure 23, page 14).

Note: If adding the G8000A series brick liner accessory, install it now. Follow instructions in G8000A accessory kit.

CAUTION: Do not pick up log base assembly by burner. This could damage burner. Only handle base by grates.

4.Route gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes.

For morevisit www..com

111604-01B

Image 13 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base AssemblyLocal Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupIncluded with Mantel Accessory Installation ClearancesAssembling and Attaching Optional Brass Trim Installing Cabinet Mantel Conventional Fireplace InstallationActual Framing Height 32 3 Front Width Depth BUILT-IN Fireplace InstallationSupport Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemCheck all other internal joints for leaks Pressure Testing Fireplace Gas ConnectionsInstalling Logs 1 Installing LogsInstalling Batteries in Receiver For Your Safety Read Before LightingInstalling Battery into Remote Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litHAND-HELD Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Specifications Wiring DiagramTechnical Service Service HintsModels LMFP33PR Illustrated Parts BreakdownKEY Part Number LMFP33PR LMFP33NR Description QTY Parts ListFirebox LMFP33PR LMFP33NR KEY Part Number Description QTY Firebox LMFP33PR and LMFP33NRBlower Accessory GA3750A GA3700TA Series AccessoriesEquipment Shutoff Valve GA5010 Information VideoOwners Registration Form Postage Required 111604-01B Warranty Information