Desa DCFTNA Installing Optional Blower Accessory GA3450TA, Reinstall top louver

Page 13

INSTALLATION

Continued

9.Use two 3" wood screws provided and attach base of fireplace to wooden mantel base (see Figure 13).

10.Remove perimeter trim kit and mantel. Be careful not to damage wall or mantel.

11.Cut an access hole in base to run flexible gas line to fireplace (see Figure 13). Make sure to locate access hole so mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

12.Install gas line. See Connecting To Gas Sup- ply, page 16.

13.Check for leaks. See Checking Gas Connec- tions, page 17.

14.Place mantel around fireplace. Be careful not to damage wall or mantel.

15.Place perimeter trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap trim over shoulder screws on fireplace (see Figure 13).

 

Hole for

 

3" Wood

 

Screw for

 

Attaching

Shoulder

Fireplace

Screw

to Mantel

Mantel

 

Base

Gas

 

 

Line

 

Access

 

Hole

 

Shoulder

 

Screws

Assembled

Hole for 3" Wood Screw

Brass Trim

for Attaching Fireplace to

 

Wooden Base

Figure 13 - Attaching Brass Trim to

Fireplace

16.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for top louver (see Figure 13).

17.Reinstall top louver.

Assembling Perimeter Trim (Perimeter trim shipped with mantel)

1.Remove packaging from three remaining pieces of trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 14.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side perimeter trim (see Figure 14).

6.While firmly holding edges of perimeter trim together, tighten both set screws on the adjust- ing plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set perimeter trim assembly aside for later installation.

Set Screws

 

 

Adjusting

 

 

Plate

 

Top Brass

 

Slot

 

Trim

 

 

Shim

 

Mitered Edge

 

 

Side Brass

 

 

Trim

 

 

Figure 14 - Assembling Brass Trim

INSTALLING OPTIONAL BLOWER ACCESSORY GA3450TA

Removing Upper Louver To install the blower accessory, you must first remove the upper louver.

1.Lift screen off fireplace and remove log set if installed.

2.Remove 4 screws from upper louver (see Figure 12, page 12). Save these screws.

3.Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside.

4.Open lower louver door by swinging door down (see Figure 12, page 12).

111244-01E

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingTools Required Phillips screwdriver Hood AssemblyHex wrench Scissors Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationBUILT-IN Fireplace Installation Installation ItemsFireplace Clearances Minimum Clearance to Combustible MaterialsDepth If you have not installed hood, follow instruc- tions onMantel Clearances for Built-In Installation Optional Mantel InstallationReinstall top louver Installing Optional Blower Accessory GA3450TAAlign shim under adjusting plate as shown in Figure Remove packaging from three remaining pieces of trimDoor Installing Blower AccessoryTest to make sure blower is working properly For Built-In InstallationLower louver Sediment Trap Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Els or page 25 for Remote-Ready Models Correct all leaks at onceInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall MountedRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyModels with One-Piece Screen Only Installing LOG SET and ScreenLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Operating BlowerAUTO/OFF/ON Blower Switch REMOTE-READY Models For Your Safety Read Before LightingOptional HAND-HELD Remote Operation If Using Optional Hand-Held RemoteAuto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Model CghrcbKey Pad Lock Feature Optional GWMS2 Wall Mounted SwitchInspecting Burners Optional GWMT1 Wall Mounted ThermostatBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole If burner flame pattern is incorrect, as shown in FigureLOG SET Wiring DiagramCabinet Observed Problem Possible Cause Remedy TroubleshootingIgnitor cable pinched or wet Ignitor cable dryMote-Ready Models Only Burner orifice is cloggedModels Only Or replace burner orificeWalls or furniture Cleaners, etc. may turn into When heated, vapors fromMote-Ready Models Only Power is low Slight smoke or odor duringFireplace produces unwanted Gas odor even when controlErs, chemicals, new carpet Ment aboveThermostat Models SpecificationsRemote-Ready Models Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List Illustrated Models Firebox Models CDCFNR, Cdcfpr Illustrated Parts Breakdown Thermostat Models FDCFTN/TP, VDCFRN/RP CDCFNR/PR REMOTE-READY Models Equipment Shutoff Valve GA5010 AccessoriesBrass Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TAWALL-MOUNT ON/OFF Switch GWMS2 WALL-MOUNT Thermostat Switch GWMT1Cleaning KIT GCK/CCK Receiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb111244-01E 111244-01E Not a UPC