INSTALLATION
Continued
6.Insert first rod into hole in left side of firebox. Fasten rod to rear hole near center of firebox us- ing black Phillips head screw (see Figure 39).
7.Insert other rod into hole on right side of fire- box and fasten rod to front hole near center of firebox using remaining sheet metal screw.
Front Center Hole for | Back Center | |
Hole for Left | ||
Right Screen Assembly | ||
Screen Assembly | ||
|
Screen |
|
Rod |
|
Rings |
|
Screen | Screen |
| Assembly |
Figure 39 - Installing Screen for Models
CDCFNR/CDCFPR
OPERATING FIREPLACE
MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.
•If you cannot reach your gas supplier, call
the fire department.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified ser- vice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING:You must operate this fireplace with the screen in place. Make sure fireplace screen is installed before run- ning fireplace.
NOTICE: During initial opera- tion of new fireplace, burning logs will give off a
1.STOP! Read the safety information starting in column 1.
2.Make sure equipment shutoff valve is fully open.
3.Turn control knob clockwise to the OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you donʼt smell gas, go to the next step.
5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 40, page 23). Note: You may be running this fireplace for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.