Desa DCFTNA WALL-MOUNT Thermostat Switch GWMT1, WALL-MOUNT ON/OFF Switch GWMS2, Information Video

Page 45

ACCESSORIES

Continued

WALL-MOUNT THERMOSTAT SWITCH GWMT1

(Not Shown)

For all remote-ready models. The desired com- fort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pilot to the heat setting selected.

WALL-MOUNT ON/OFF SWITCH GWMS2

(Not Shown)

For all remote-ready models. Allows the fire- place to be turned on and off with a wall switch.

CORNER MANTEL WITH FULL HEARTH BASE

CMA208F Series - Dark Oak CMA209U Series - Unfinished Birch

For all models. Space-saving mantel and hearth base corner design features clean, classic lines. Available in french walnut finish or an unfinished hardwood, ready to stain or paint. Complete as- sembly instructions included. Three-sided trim kit included.

Dimensions (WxHxD): 47 1/2" x 42 3/4" x 29 1/2"

CABINET MANTEL AND FULL HEARTH BASE

GMC80F Series - Oak Finished

CMA200F Series - Oak Finished GMC81U Series - Unfinished Birch GMC82F Series - Cherry Finished Birch For all models. Mantel features columns, mold- ings and fluting. Three-sided trim kit included

Dimensions (WxHxD): 50" x 43" x 22"

CLEANING KIT - GCK/CCK

(Not Shown)

For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTB AND CGHRCTB

For all remote-ready models. Allows the fire- place to be operated in a manually or thermostati- cally controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - GHRCB AND CGHRCB

For all remote-ready models. Allows the fire- place to be turned on and off by using a hand-held remote control.

INFORMATION VIDEO - 108917-01

For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint. com.

FIRE CRACKLE - CF6-A

(Not Shown)

For all models. Creates the sound of a real burn- ing fire.

111244-01E

www.desatech.com

45

Image 45
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingHood Assembly Tools Required Phillips screwdriverHex wrench Scissors AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationBUILT-IN Fireplace Installation Installation ItemsFireplace Clearances Minimum Clearance to Combustible MaterialsDepth If you have not installed hood, follow instruc- tions onMantel Clearances for Built-In Installation Optional Mantel InstallationReinstall top louver Installing Optional Blower Accessory GA3450TAAlign shim under adjusting plate as shown in Figure Remove packaging from three remaining pieces of trimDoor Installing Blower AccessoryFor Built-In Installation Test to make sure blower is working properlyLower louver Sediment Trap Connecting to GAS SupplyConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededChecking GAS Connections Els or page 25 for Remote-Ready Models Correct all leaks at onceInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall MountedRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyModels with One-Piece Screen Only Installing LOG SET and ScreenLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Operating BlowerAUTO/OFF/ON Blower Switch REMOTE-READY Models For Your Safety Read Before LightingOptional HAND-HELD Remote Operation If Using Optional Hand-Held RemoteAuto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Model CghrcbKey Pad Lock Feature Optional GWMS2 Wall Mounted SwitchInspecting Burners Optional GWMT1 Wall Mounted ThermostatBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole If burner flame pattern is incorrect, as shown in FigureWiring Diagram LOG SETCabinet Observed Problem Possible Cause Remedy TroubleshootingIgnitor cable pinched or wet Ignitor cable dryMote-Ready Models Only Burner orifice is cloggedModels Only Or replace burner orificeWalls or furniture Cleaners, etc. may turn into When heated, vapors fromMote-Ready Models Only Power is low Slight smoke or odor duringFireplace produces unwanted Gas odor even when controlErs, chemicals, new carpet Ment aboveSpecifications Thermostat ModelsRemote-Ready Models Service Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List Illustrated Models Firebox Models CDCFNR, Cdcfpr Illustrated Parts Breakdown Thermostat Models FDCFTN/TP, VDCFRN/RP CDCFNR/PR REMOTE-READY Models Equipment Shutoff Valve GA5010 AccessoriesBrass Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TAWALL-MOUNT ON/OFF Switch GWMS2 WALL-MOUNT Thermostat Switch GWMT1Cleaning KIT GCK/CCK Receiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb111244-01E 111244-01E Not a UPC