INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD

REMOTE CONTROL ACCESSORIES

Remote-Ready Models Only

([C]GHRCB Series & [C]GHRCTB

Series)

Installing Receiver

1.Disconnect wires from the control valve (see Figure 27) .

2.Locate the battery clip mounted on the back of the receiver (see Figure 28).

3.Slide 9-volt battery (not included) through the clip.

4.Attach the terminal wires to the battery (see Figure 28).

5.Connect wires from remote receiver to control valve as shown in Figure 29.

6.Install remote receiver unit onto remote/ blower bracket using screws provided (see Figure 29).

Figure 27 - Disconnecting Wires From

Control Valve

Receiver

9-Volt

Terminal

Battery

Wires

 

Battery Clip

Figure 28 - Attaching Battery to Receiver

White Wire to

TH Terminal on

Control Valve

Remote

Receiver

Red Wire to

TPTH Terminal on

Control Valve

Figure 29 - Installing Remote Receiver

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not includ- ed). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Terminal

Battery Cover

Remote

 

 

 

 

Control Unit

Wires

 

 

 

 

 

9-Volt

 

 

 

Battery

 

 

 

 

 

Battery

 

 

Housing

Figure 30 - Installing Battery in Hand-

Held Remote Control Unit (GHRCB and

 

CGHRCB Series)

 

Terminal Wires

Remote

Control Unit

 

 

9-Volt

 

 

 

Battery

 

 

 

 

 

 

Battery

Battery

 

 

Cover

 

 

 

Housing

 

 

Figure 31 - Installing Battery in Hand-

Held Remote Control Unit (GHRCTB and

 

CGHRCTB Series)

 

OPTIONAL WALL MOUNTED

THERMOSTAT - GWMT1

 

(Remote-Ready Models Only)

WARNING: Read and fol-

low installation instructions.

Installation should be done by

a qualified installer familiar with

low-voltage wiring procedures.

WARNING: Do not connect

this thermostat to any electrical

source! Electrical shock and/or

fire hazard will occur.

 

1.Remove jumper wire from control valve (see Figure 27).

111244-01E

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesTools Required Phillips screwdriver Hood AssemblyHex wrench Scissors Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Clearance to Combustible Materials Installation ItemsBUILT-IN Fireplace Installation Fireplace ClearancesDepth If you have not installed hood, follow instruc- tions onMantel Clearances for Built-In Installation Optional Mantel InstallationRemove packaging from three remaining pieces of trim Installing Optional Blower Accessory GA3450TAReinstall top louver Align shim under adjusting plate as shown in FigureDoor Installing Blower AccessoryTest to make sure blower is working properly For Built-In InstallationLower louver Sediment Trap Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Els or page 25 for Remote-Ready Models Correct all leaks at onceOptional Wall Mounted Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyModels with One-Piece Screen Only Installing LOG SET and ScreenLighting Instructions Operating FireplaceOperating Blower Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationAUTO/OFF/ON Blower Switch REMOTE-READY Models For Your Safety Read Before LightingOptional HAND-HELD Remote Operation If Using Optional Hand-Held RemoteON/OFF Series Model Cghrcb Manual ModeAuto Thermostatic Mode Auto Shutoff FeatureOptional GWMT1 Wall Mounted Thermostat Optional GWMS2 Wall Mounted SwitchKey Pad Lock Feature Inspecting BurnersIf burner flame pattern is incorrect, as shown in Figure Cleaning MaintenanceBurner Flame Pattern Burner Injector Holder and Pilot AIR Inlet HoleLOG SET Wiring DiagramCabinet Ignitor cable dry TroubleshootingObserved Problem Possible Cause Remedy Ignitor cable pinched or wetOr replace burner orifice Burner orifice is cloggedMote-Ready Models Only Models OnlySlight smoke or odor during When heated, vapors fromWalls or furniture Cleaners, etc. may turn into Mote-Ready Models Only Power is lowMent above Gas odor even when controlFireplace produces unwanted Ers, chemicals, new carpetThermostat Models SpecificationsRemote-Ready Models Parts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List Illustrated Models Firebox Models CDCFNR, Cdcfpr Illustrated Parts Breakdown Thermostat Models FDCFTN/TP, VDCFRN/RP CDCFNR/PR REMOTE-READY Models THERMOSTAT-CONTROLLED Blower KIT GA3450TA AccessoriesEquipment Shutoff Valve GA5010 Brass Trim KIT GA6095Receiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCK/CCK111244-01E 111244-01E Not a UPC