Desa VDCFTPB, VDCFRNB Installing Receiver, Receiver Volt Terminal Battery Wires Battery Clip

Page 19

INSTALLATION

Continued

OPTIONAL Wireless hand-held REMOTE CONTROL ACCESSORies Remote-Ready Models Only (HRC100 Series & HRC200 Series)

Installing Receiver

1. Disconnect wires from the control valve (see Figure 26) .

2. Locate the battery clip mounted on the back of the receiver (see Figure 27).

3. Slide 9-volt battery (not included) through the clip.

4. Attach the terminal wires to the battery (see Figure 27).

5. Connect wires from remote receiver to control valve as shown in Figure 28.

6. Install remote receiver unit onto remote/ blower bracket using screws provided (see Figure 28).

Figure 26 - Disconnecting Wires From

Control Valve

Receiver

9-Volt

Terminal

Battery

Wires

 

Battery Clip

Figure 27 - Attaching Battery to Receiver

White Wire to

TH Terminal on

Control Valve

Remote

Receiver

Red Wire to

TPTH Terminal on

Control Valve

Figure 28 - Installing Remote Receiver

Installing 9-Volt Battery in Hand-Held

Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Battery

Remote Control Unit

Cover

Terminal

Wires

Battery

Housing

9-Volt Battery

Figure 29 - Installing Battery in Hand-

Held Remote Control Unit

optional Wall Mounted Thermostat - GWMT1 (Remote-Ready Models Only)

WARNING: Read and fol- low installation instructions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 26).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 30, page 20.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall).

IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace or heat and air conditioning ducts.

116526-01B

www.desatech.com

19

Image 19
Contents Thermostat Models Vdcftnb and Vdcftpb Remote-Ready Models Shown with Optional Cabinet Mantel/Hearth Base AccessoryVdcfrpb and Vdcfrnb Table of Contents Safety Information Safety Information Local Codes Optional Remote Control AccessoriesProduct Features Product IdentificationAir for Combustion Ventilation Hood AssemblyProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Clearance to Combustible Materials InstallationInstallation Items Fireplace ClearancesDepth Built-In Fireplace InstallationActual Framing Height Front WidthTop Louver Bottom Louver Optional Mantel InstallationMantel Shelf Side of FireboxRemoving Upper Louver Installing Optional Blower Accessory GA3450TARemote Blower Bracket Switch Plate Screw Installing Blower AccessoryOpen lower louver door by swinging door down see , Extension Cord For Built-In InstallationBlower Bracket Connecting to GAS Supply Installation Items Needed Connecting equipment shutoff valve to heater controlChecking GAS Connections Gas Meter Pressure Testing Fireplace Gas ConnectionsEquipment Open Shutoff Valve Closed Gas Regulator or Gas Control Valve EquipmentReceiver Volt Terminal Battery Wires Battery Clip Installing ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Terminal W Terminal R Optional Wall Switch GWMS2 Remote-Ready Models OnlyControl Valve To Wall Thermostat or Switch Feed wires through rectangular slotsLighting Instructions Installing LOG SET and ScreenFor Your Safety Read Before Lighting Operating FireplaceThermostat Control Operation Manual Lighting ProcedureOperating Fireplace To Turn OFF GAS To ApplianceOperating Blower AUTO/OFF/ON SwitchPilot Ignitor Burner Electrode Piezo Flame Control Ignitor Button Adjustment KnobPilot Burner Ignitor Electrode HRC200 Optional Hand-HeldRemote Operation Thermostat Series ModelOptional GWMT1 Wall mounted Thermostat Optional GWMS2 Wall Mounted SwitchBurner Flame Pattern Cleaning MaintenanceInspecting Burners Pilot Flame PatternCabinet Cleaning MaintenanceWiring Diagram LOG SetObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Initial operation Processes and log curing When heated, vapors fromMote-Ready Models Only Power is low Slight smoke or odor duringGas leak. See Warning Rating Variable 17,000/26,000 Btu/Hr SpecificationsThermostat Models Remote-Ready Models Rating Variable 17,000/30,000 Btu/HrFirebox Models VDC Illustrated Parts BreakdownOuter Casing Parts ListOuter Casing Top BaffleThermostat Models Illustrated Parts BreakdownVdcftpb and Vdcftnb Parts List Vdcfrnb and Vdcfrpb REMOTE-READY ModelsBrass Flare Adapter Fitting Equipment Shutoff Valve GA5010 AccessoriesTHERMOSTAT-CONTROLLED Blower KIT GA3450T WALL-MOUNT ON/OFF Switch AccessoriesWALL-MOUNT Thermostat Parts Under Warranty Replacement PartsService Hints Technical Service116526-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth