Desa VDCFRPB, VDCFRNB, VDCFTPB installation manual Gas leak. See Warning

Page 32

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Fireplace produces unwanted

1. Fireplace burning vapors from

1.

Open window to ventilate

odors

 

paint, hair spray, glues, clean-

 

room. Stop using odor caus-

 

 

 

ers, chemicals, new carpet,

 

ing products while fireplace

 

 

 

etc. (See IMPORTANT state-

 

is running

 

 

2.

ment above)

2.

Refill supply tank (propane/LP

 

 

Low fuel supply (propane/LP

 

 

3.

only)

3.

only)

 

 

Gas leak. See Warning state-

Locate and correct all leaks

 

 

 

ment at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 17)

 

 

 

 

 

 

Fireplace shuts off in use (ODS

1. Not enough fresh air is

1.

Open window and/or door for

operates)

2.

available

2.

ventilation

 

 

Low line pressure

Contact local natural or pro-

 

 

3.

O D S / pi l o t i s pa rt i a l l y

3.

pane/LP gas company

 

 

Clean ODS/pilot (see Cleaning

 

 

 

clogged

 

and Maintenance, page 27)

 

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

 

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

2.

Control valve defective

2.

tions, page 17)

 

 

Replace control valve

 

 

 

 

 

Gas odor during combustion

1. Foreign matter between con-

1.

Take apart gas tubing and

 

 

2.

trol valve and burner

2.

remove foreign matter

 

 

Gas leak. See Warning

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 17)

32

www.desatech.com

116526-01B

Image 32
Contents Vdcfrpb and Vdcfrnb Shown with Optional Cabinet Mantel/Hearth Base AccessoryThermostat Models Vdcftnb and Vdcftpb Remote-Ready Models Table of Contents Safety Information Safety Information Optional Remote Control Accessories Product FeaturesProduct Identification Local CodesHood Assembly Air for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeInstallation Installation ItemsFireplace Clearances Minimum Clearance to Combustible MaterialsBuilt-In Fireplace Installation Actual Framing HeightFront Width DepthOptional Mantel Installation Mantel ShelfSide of Firebox Top Louver Bottom LouverInstalling Optional Blower Accessory GA3450TA Removing Upper LouverOpen lower louver door by swinging door down see , Installing Blower AccessoryRemote Blower Bracket Switch Plate Screw Blower Bracket For Built-In InstallationExtension Cord Connecting to GAS Supply Checking GAS Connections Connecting equipment shutoff valve to heater controlInstallation Items Needed Pressure Testing Fireplace Gas Connections Equipment Open Shutoff Valve ClosedGas Regulator or Gas Control Valve Equipment Gas MeterInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing ReceiverReceiver Volt Terminal Battery Wires Battery Clip Optional Wall Switch GWMS2 Remote-Ready Models Only Control Valve To Wall Thermostat or SwitchFeed wires through rectangular slots Terminal W Terminal RInstalling LOG SET and Screen For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsManual Lighting Procedure Operating FireplaceTo Turn OFF GAS To Appliance Thermostat Control OperationAUTO/OFF/ON Switch Operating BlowerPilot Burner Ignitor Electrode Piezo Flame Control Ignitor Button Adjustment KnobPilot Ignitor Burner Electrode Optional Hand-Held Remote OperationThermostat Series Model HRC200Optional GWMS2 Wall Mounted Switch Optional GWMT1 Wall mounted ThermostatCleaning Maintenance Inspecting BurnersPilot Flame Pattern Burner Flame PatternCleaning Maintenance Wiring DiagramLOG Set CabinetTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting When heated, vapors from Mote-Ready Models Only Power is lowSlight smoke or odor during Initial operation Processes and log curingGas leak. See Warning Specifications Thermostat Models Remote-Ready ModelsRating Variable 17,000/30,000 Btu/Hr Rating Variable 17,000/26,000 Btu/HrIllustrated Parts Breakdown Firebox Models VDCParts List Outer Casing TopBaffle Outer CasingVdcftpb and Vdcftnb Illustrated Parts BreakdownThermostat Models Parts List REMOTE-READY Models Vdcfrnb and VdcfrpbBrass Flare Adapter Fitting THERMOSTAT-CONTROLLED Blower KIT GA3450T AccessoriesEquipment Shutoff Valve GA5010 WALL-MOUNT Thermostat AccessoriesWALL-MOUNT ON/OFF Switch Replacement Parts Service HintsTechnical Service Parts Under Warranty116526-01B Limited Warranty VENT-FREE Compact Classic Hearth Warranty InformationKeep this Warranty