Venting Installation
instructions
Continued
High Altitude Installation
Your
When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice for your location.
For assistance with any high altitude installation contact DESA Customer Service Department at
Parts lists for venting kits and components
DESA (5/8") Pipe & Vent Kits
Number | Description |
|
|
6" Section Double Wall Pipe, Galvanized | |
12" Section Double Wall Pipe, Galvanized | |
24" Section Double Wall Pipe, Galvanized | |
36" Section Double Wall Pipe, Galvanized | |
48" Section Double Wall Pipe, Galvanized | |
Adjustable | |
6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe | |
| Section) |
6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe | |
| Section |
45° Elbow, Galvanized | |
90° Elbow, Galvanized | |
45° Starter Elbow, Galvanized (Duravent Collar to FMI | |
| Pipe) |
45° Starter Elbow, Galvanized (FMI Collar to Duravent | |
| Pipe) |
Ground Floor Vent Kit | |
Basement Vent Kit | |
Snorkel Kit | |
Roof Vent Kit | |
Corner Vent Kit | |
HTK | Horizontal Round Termination Kit |
Horizontal Round Termination Kit, Galvanized | |
Horizontal Square Termination Kit, Galvanized | |
| Horizontal Square Termination Kit |
Vertical Round Termination, Galvanized | |
14" Snorkel Termination, Galvanized | |
36" Snorkel Termination, Galvanized | |
Storm Collar - Galvanized | |
Wall Firestop - Galvanized | |
Roof Flashing - 0 to 6/12 Pitch - Galvanized | |
Roof Flashing - 6/12 to 12/12 Pitch - Galvanized |
Number | Description |
Vertical Restrictor - Galvanized | |
Vinyl Siding Standoff - Galvanized | |
Wall Strap | |
Cathedral Ceiling Support | |
Firestop Plate | |
Stucco Flashing - For use with |
Fireplace Installation
CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 29).
Installing optional blower accessories
NOTICE: The
NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this.
WARNING: If there is a duplex electrical outlet in- stalled in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).
2.Attach green ground wire from power cord to blower housing us- ing screw provided (see Figure 25). Tighten screws securely.
|
| Blower |
|
| Location |
| Lower Firebox |
|
| Cavity |
|
Side View | Spade |
|
| Magnetic | |
| Terminals | |
|
| Strips |
Exhaust |
Port |
Green
Ground Wire
Screw
Figure 25 - Blower Model BK
14 | www.desatech.com |