Desa V42V-A Replacement Parts, Service Hints, Technical Service, Specifications

Page 28

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

Service Hints

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Customer Service Depart- ment at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA’s technical service web site at www.desatech.com.

Specifications

 

V42N-A

 

V42P-A

Rating

VV42NB(1)

CHDV42NR-B

VV42PB(1)

25,000/35,000 Btu/hr

25,000/35,000 Btu/hr

23,000/33,000 Btu/hr

Gas Type

Natural

Natural

Propane/LP

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

3.5" w.c.

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

5.5" w.c.

5.5" W.C.

11.0" w.c.

Dimension (HxWxD)

 

 

 

Fireplace (Actual size of

40" x 48" x 23 1/2"

40" x 48" x 23 1/2"

40" x 48" x 23 1/2"

firebox. Measurements do not

include nailing flanges or

101.6 x 121.9 x 59.9 cm

101.6 x 121.9 x 59.9 cm

101.6 x 121.9 x 59.9 cm

standoffs).

 

 

 

Carton

41" x 51" x 24"

41" x 51" x 24"

41" x 51" x 24"

Weight, lbs/kg*

104.1 x 129.5 x 61 cm

104.1 x 129.5 x 61 cm

104.1 x 129.5 x 61 cm

145 lbs/55 kg

215 lbs/97.5 kg

145 lbs/55 kg

Fireplace

Shipping

148 lbs/56 kg

218 lbs/99 kg

148 lbs/56 kg

28

www.desatech.com

111906-01F

Image 28
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Fireplace Installation High Altitude InstallationParts lists for venting kits and components Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsInstalling Brick liner Models BL42DASA and BL42DHASA Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Rear Brick PanelOperating Fireplace For your safety read Before lightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationThermostat Series Model HRC200 Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Cleaning Maintenance Pilot assemblyInspecting Burners Burner Flame PatternTroubleshooting To clean pilot. This can damage pilot unitPilot and burners LogsTroubleshooting Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Parts List 108331-01 108331-02 109082-02Illustrated Parts Breakdown VV42PHB1 and CHDV24NR-B 111906-01F 111906-01F Warranty Information Keep this Warrant