Desa V42V-A Installing Remote Receiver, Pressure Testing Fireplace Gas Connections

Page 18

Fireplace Installation

Continued

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 or 35). Apply noncor- rosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Propane/LP Equipment

Supply Tank Shutoff

Valve

Gas Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas

Fireplace

Installing optional Wireless Hand- Held Remote Control - HRC100 AND HRC200 SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 36).

4.Attach the terminal wires to the battery.

5.Remove wires from TH to TPTH on control valve (see Figure 37).

6.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

7.Replace the switch bracket.

Receiver

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33, page 17).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, page 21). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 22).

9-Volt

Terminal

Alkaline

Battery

Wires

 

Battery Clip

Figure 36 - Attaching Alkaline Battery to Receiver

Figure 37 - Connecting Wall Switch to Control Cover

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

18

www.desatech.com

111906-01F

Image 18
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Features Product IdentificationLocal Codes Pre-Installation Preparation Location and space requirementsClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Venting with One 90 ElbowVertical Venting Parts lists for venting kits and components Fireplace InstallationHigh Altitude Installation Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Rear Brick PanelFor your safety read Before lighting Operating FireplaceLighting Instructions OpTIONAL Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOperating optional blower accessory Thermostat Series Model HRC200Operating optional GWMT1 Wall Mounted Thermostat Inspecting Burners Cleaning MaintenancePilot assembly Burner Flame PatternPilot and burners TroubleshootingTo clean pilot. This can damage pilot unit LogsTroubleshooting Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown Parts List 108331-01 108331-02 109082-02Illustrated Parts Breakdown VV42PHB1 and CHDV24NR-B 111906-01F 111906-01F Warranty Information Keep this Warrant