6

Installation Assembly/

Leak Testing Procedure

Perform a leak test at least once a year whether the gas supply cylinder has been disconnected or not. In addition, whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is disconnected or replaced, perform a leak test.

As a safety precaution, remember to always leak test your fireplace or firepit outdoors in a well-ventilated area. Never smoke or permit sources of ignition in the area while doing a leak test. Do not use a flame, such as a lighted match to test for leaks. Use a solution of soapy water.

1.Prepare a leak testing solution of soapy water by mixing in a spray bottle one part liquid soap to one part water.

2.Make sure all the control knobs are in the OFF position.

3.Turn on the gas.

On natural gas systems, turn the main feed valve to the burn- er.

On LP systems, turn the cylinder valve knob counter clockwise one turn to open.

4.Apply the leak-testing solution by spraying it on joints of the gas delivery system. Blowing bubbles in the soap solution indicates that a leak is present.

5.Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer. Do not attempt to repair the cylinder valve if it is damaged. The cylinder must be replaced.

6.Turn the control knob back to the full OFF position.

If you are unable to stop a leak:

1.Turn the control knob back to the full OFF position.

2.Shut off the gas supply to the fireplace or firepit and release pres- sure in the hose and manifold by turning the control valve one quarter turn counter-clockwise.

3.On LP systems, remove the cylinder from the fireplace or firepit.

4.Call an authorized gas appliance service technician or an LP gas dealer.

Do not use the appliance until the leak is corrected.

2009 Fireplaces and Firepits

www.calspas.com

LTR20091006, Rev. B

Image 8
Contents Page Operation InstallationMaintenance Appendix Safety Instructions Placement and LocationSet-Up Maintenance and Repair Precautions Regarding Children StorageInstallation LocationLeak Testing Procedure Liquid Propane LP RequirementsInstallation Assembly Connection Installation Natural GasFireplace Burner Installation Installation Assembly Fire Pit Burner Installation Installation Assembly Fireplace Log Set Placement Fire on Ice Glass Placement High Elevation Installation Natural Gas ConversionInstallation Assembly For your safety, read before lighting OperationUsing GrillYour Lighting Instructions for Automatic StarterWhat To Do If You Smell Gas To Turn Off GasLighting Your Wood Burning Fireplace Maintenance Fireplace Parts Replacement PartsAppendix Firepit Parts Specifications Fireplace SpecificationsWarranty Warranty Conditions and LimitationsWarranty Exclusions Fireplaces and Firepits Contact Information