Specifications

Fireplace Specifications

 

LP Gas

Natural Gas

 

 

 

Max.. Input BTU/

51,037

55,000

Hr

 

 

Orifice Size

#42 (0.0860)

#26 (0.147)

 

 

 

Manifold Pressure

10” Water Column

7” Water Column

 

 

 

Maximum Gas

11” Water Column

7” Water Column

Supply Pressure

 

 

 

 

 

Maximum Inlet

13” Water Column

7” Water Column

Supply Pressure

 

 

 

 

 

Regulator Pre-Set

11” Water Column

3.5” Water Column

 

 

 

Fire Pit Specifications

 

LP Gas

Natural Gas

 

 

 

Max.. Input BTU/

51,037

55,000

Hr

 

 

Orifice Size

#42 (0.0860)

#26 (0.147)

 

 

 

Manifold Pressure

10” Water Column

7” Water Column

 

 

 

Maximum Gas

11” Water Column

7” Water Column

Supply Pressure

 

 

 

 

 

Maximum Inlet

13” Water Column

7” Water Column

Supply Pressure

 

 

 

 

 

Regulator Pre-Set

11” Water Column

3.5” Water Column

 

 

 

2009 Fireplaces and Firepits

www.calspas.com

LTR20091006, Rev. B

Image 28
Contents Page Maintenance Appendix InstallationOperation Safety Instructions Placement and LocationSet-Up Maintenance and Repair Precautions Regarding Children StorageInstallation LocationLeak Testing Procedure Liquid Propane LP RequirementsInstallation Assembly Connection Installation Natural GasFireplace Burner Installation Installation Assembly Fire Pit Burner Installation Installation Assembly Fireplace Log Set Placement Fire on Ice Glass Placement High Elevation Installation Natural Gas ConversionInstallation Assembly For your safety, read before lighting OperationUsing GrillYour Lighting Instructions for Automatic StarterWhat To Do If You Smell Gas To Turn Off GasLighting Your Wood Burning Fireplace Maintenance Appendix Replacement PartsFireplace Parts Firepit Parts Specifications Fireplace SpecificationsWarranty Warranty Conditions and LimitationsWarranty Exclusions Fireplaces and Firepits Contact Information