Liquid Propane (LP)

Requirements

The 20 lb LP gas supply cylinder used with LP models must be con- structed and marked in accordance with the specifications for LP-gas cylinders as required by the U.S. Department of Transportation (DOT) or the CAN/CSA B339, Cylinders, Spheres and Tubes for the Transpor- tation of Dangerous Goods.

Manifold Pressure: For plumbed-in LP installation, use a regulator.

Supply Pressure: Maximum line pressure for plumbed-in propane is 14” W.C psi (3.5 kPa). Minimum line pressure for propane is 11” W.C.

Pressure Regulator: The unit must be used with the gas pressure regulator. The regulator will control and maintain a uniform gas pres- sure in the manifold. The burner orifice has been sized for the gas pressure delivered by the regulator.

Cylinder Specification: Any LP gas supply cylinder used with this firepit or fireplace must be approximately 12 inches in diameter and 18 inches high. The maximum fuel capacity is 20 lbs. of propane, or

5 gallons. Full cylinder weight should be approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always use the cylinder dust cap on the cylinder valve outlet during transport and when the cylinder is not connected to the firepit or fireplace.

Transporting Gas Cylinder: Only one cylinder should be transport- ed at a time. Transport cylinder in an upright and secure manner with control valve turned off and the dust cap in place.

Enclosures: Ensure cylinder valves are always readily accessible. A door on the enclosure to gain access to the cylinder valve is accept- able, provided it is non-locking and can be opened without the use of tools.

If you build an enclosure for an LP gas cylinder, follow these recom- mended specifications and follow local codes.

Enclosures for LP gas supply cylinders need to be ventilated by open- ings at the level of the cylinder valve and at floor level. This is accom- plished by:

1)Having one side of the enclosure shall be completely open,

Or, for an enclosure with four sides, a top and bottom:

2009 Fireplaces and Firepits

7

Installation / Assembly

LTR20091006, Rev. B

www.calspas.com

Image 9
Contents Page Installation Maintenance AppendixOperation Placement and Location Safety InstructionsSet-Up Maintenance and Repair Storage Precautions Regarding ChildrenLocation InstallationLeak Testing Procedure Requirements Liquid Propane LPInstallation Assembly Connection Natural Gas InstallationFireplace Burner Installation Installation Assembly Fire Pit Burner Installation Installation Assembly Fireplace Log Set Placement Fire on Ice Glass Placement Natural Gas Conversion High Elevation InstallationInstallation Assembly Operation For your safety, read before lightingLighting Instructions for Automatic Starter Using GrillYourTo Turn Off Gas What To Do If You Smell GasLighting Your Wood Burning Fireplace Maintenance Replacement Parts AppendixFireplace Parts Firepit Parts Fireplace Specifications SpecificationsWarranty Conditions and Limitations WarrantyWarranty Exclusions Fireplaces and Firepits Contact Information