Coleman 9992-449 system manual Screws Under lip

Page 4

Liquid Propane Gas Conversion Instructions

5.Remove the screws from the bottom of the heat shield, holding the front heat shield in place. The screws are located under the bottom lip of the shield (Fig. 5).

6.Remove the side heat shield screws located under the bottom lip of the heat shield. Remove all of the top heat shield screws (Fig. 6).

7.Remove the front heat shield (Fig. 7).

8.Grasp and push the burners towards the rear of the grill to detach the burner from the

valves (Fig. 8).

9.Angle the burners up and remove (Fig. 8).

Fig 5

Screws

under lip

Side Screws

(Repeat on left side)

Fig 6

Fig 7

Tabs

Fig 8

4

Image 4
Contents Liquid Propane Conversion Kit Liquid Propane Gas Conversion Instructions Tools Needed Screws Under lip Flex Line Gas Inlet Flex Line Manifold Screws You are now ready to install New LP manifold Installing the L.P. regulator Pipe dope should not be used on any flared fittingsConverting the Rear Infrared Burner to LP Installation is now complete Enjoy your grill safely Label the GrillLiquid Propane Gas Conversion Instructions Liquid Propane Gas Conversion Instructions 9992-449 8/14/06