Coleman 9992-449 system manual Flex Line Gas Inlet Flex Line Manifold Screws

Page 5

Liquid Propane Gas Conversion Instructions

10.Disconnect the right side flexline from the manifold using the adjustable wrench. This will free up the right side of the manifold (Fig. 9).

11.Disconnect the left side flexline from the back infrared valve using an adjustable wrench. This will free up the left side of the manifold (Fig. 10).

12.Remove the control knobs from the front of the grill (Fig. 11).

13.Remove the two screws holding each bezel in place on the control panel (Fig. 12).

14.Remove the bezels from the front control panel. Note: The small bezel stays in place (Fig. 13).

15.Remove manifold from grill body (Fig. 14).

Flex Line

Fig 9

Gas Inlet Flex Line

Manifold

Fig 10

Fig 11

Screws

Fig 12

Manifold

Fig 14

Fig 13

5

Image 5
Contents Liquid Propane Conversion Kit Liquid Propane Gas Conversion Instructions Tools Needed Screws Under lip Flex Line Gas Inlet Flex Line Manifold Screws You are now ready to install New LP manifold Pipe dope should not be used on any flared fittings Installing the L.P. regulatorConverting the Rear Infrared Burner to LP Label the Grill Installation is now complete Enjoy your grill safelyLiquid Propane Gas Conversion Instructions Liquid Propane Gas Conversion Instructions 9992-449 8/14/06