Electrolux EHG 6832, EHG 6402, EHG 6412 manual Something Not Working?, Symptom

Page 14

14electrolux

Something Not Working?

If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre.

SYMPTOM

SOLUTION

„There is no spark when ‹ Check that the unit is plugged

lighting the gas.

in and the electrical supply is

 

switched on.

‹ Check that the RCCB has not

 

tripped (if fitted).

‹

Check the mains fuse has not

 

blown.

‹

Check the burner cap and

 

crown have been replaced

 

correctly, e.g. after cleaning.

„The gas ring burns unevenly. ‹ Check the main jet is not blocked and the burner crown is clear of food particles.

‹Check the burner cap and crown have been replaced correctly, e.g. after cleaning.

If after all these checks, your hob still does not operate correctly, contact your local Service Force Centre.

Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls.

In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.

Image 14
Contents Instruction booklet Page Welcome to the world of Electrolux Contents People Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hob Instructions for the User Lighting the burners OperationHob burners control knobs Only for models EHG 641, EHG 6412, EHGElectrolux Using the hob correctly Burner Minimum Maximum DiameterPan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements Provision for VentilationInstallation Gas Connection Location Fitting the Hob into the Worktop SealBuilding over a kitchen unit with door BuildingBuilding over a cupboard or drawer Electrical Connections This HOB Must be EarthedPermanent Connection Wiring diagram Fault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Minimum adjustment Pressure TestingProcedure CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions ExclusionsService and Spare Parts 0870 5 929European Guarantee Electrolux Page 35693-1702 10/07 R.A