A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight.

B.INSULATION CHECK

Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated

-a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

Image 27
Contents Instruction booklet Page Welcome to the world of Electrolux Contents During Use Important Safety InformationInstallation People SafetyEnvironmental Information ServiceDescription of the Hob Instructions for the User Only for models EHG 641, EHG 6412, EHG OperationHob burners control knobs Lighting the burnersElectrolux Burner Minimum Maximum Diameter Using the hob correctlyMaintenance and Cleaning Hob TopPan Supports Ignition electrode BurnersSomething Not Working? SymptomEngineer technical data Instructions for the InstallerType of GAS Provision for Ventilation Important safety requirementsInstallation Gas Connection Location Seal Fitting the Hob into the WorktopBuilding Building over a cupboard or drawerBuilding over a kitchen unit with door This HOB Must be Earthed Electrical ConnectionsPermanent Connection Wiring diagram Preliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignition System / Gas Ignition Commissioning Pressure TestingProcedure Minimum adjustmentMethod Conversion from Natural Gas to LPGExclusions Standard Guarantee Conditions0870 5 929 Service and Spare PartsEuropean Guarantee Electrolux Page 35693-1702 10/07 R.A