Electrolux EHG 6402, EHG 6412, EHG 6832 manual Type of GAS

Page 16

16 electrolux

BURNER

RAPID

SEMI-RAPID A U X I L I A R Y TRIPLECROWN

TYPE OF GAS

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

M A X

MIN

M A X

MIN

M A X

MIN

M A X

MIN

 

NOMINALTHERMAL

 

 

 

 

 

 

 

 

NATURAL GAS

POWER

kW

3.0

0.75

2.0

0.45

1.0

0.33

4.0

1.2

 

 

 

 

 

 

 

 

 

 

20 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.286

0.057

0.190

0.038

0.095

0.028

0.381

0.114

37.78 MJ/m3

NOZZLEREFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

Ws - 50.7 MJ/ m3

1/100mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPG GAS

NOMINALTHERMAL

 

 

 

 

 

 

 

 

POWER

kW

2.8

0.75

2.0

0.45

1.0

0.33

4.0

1.2

28-30/37 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

 

 

RATE

g/h

202 43.5

144

29

72

21,5

291

86

49.92 MJ/Kg

 

NOZZLEREFERENCE

86

42

71

32

50

28

98

56

 

1/100mm

 

 

 

 

 

 

 

 

 

Image 16
Contents Instruction booklet Page Welcome to the world of Electrolux Contents Important Safety Information InstallationPeople Safety During UseService Environmental InformationDescription of the Hob Instructions for the User Operation Hob burners control knobsLighting the burners Only for models EHG 641, EHG 6412, EHGElectrolux Using the hob correctly Burner Minimum Maximum DiameterHob Top Maintenance and CleaningPan Supports Burners Ignition electrodeSymptom Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements Provision for VentilationInstallation Gas Connection Location Fitting the Hob into the Worktop SealBuilding over a cupboard or drawer BuildingBuilding over a kitchen unit with door Electrical Connections This HOB Must be EarthedPermanent Connection Wiring diagram Fault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing ProcedureMinimum adjustment CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions ExclusionsService and Spare Parts 0870 5 929European Guarantee Electrolux Page 35693-1702 10/07 R.A