16 electrolux
BURNER | RAPID |
TYPE OF GAS |
|
|
|
|
|
|
|
|
|
| |
| POSITION |
| M A X | MIN | M A X | MIN | M A X | MIN | M A X | MIN | |
| NOMINALTHERMAL |
|
|
|
|
|
|
|
| ||
NATURAL GAS | POWER | kW | 3.0 | 0.75 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | |
|
|
|
|
|
|
|
|
|
| ||
20 mbar | NOMINALFLOW |
|
|
|
|
|
|
|
|
| |
VALUE = | RATE | m3/h | 0.286 | 0.057 | 0.190 | 0.038 | 0.095 | 0.028 | 0.381 | 0.114 | |
37.78 MJ/m3 | NOZZLEREFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | 146 | Adjust. | ||
Ws - 50.7 MJ/ m3 | |||||||||||
1/100mm |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
LPG GAS | NOMINALTHERMAL |
|
|
|
|
|
|
|
| ||
POWER | kW | 2.8 | 0.75 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | ||
NOMINALFLOW |
|
|
|
|
|
|
|
|
| ||
VALUE = |
|
|
|
|
|
|
|
|
| ||
RATE | g/h | 202 43.5 | 144 | 29 | 72 | 21,5 | 291 | 86 | |||
49.92 MJ/Kg | |||||||||||
| NOZZLEREFERENCE | 86 | 42 | 71 | 32 | 50 | 28 | 98 | 56 | ||
| 1/100mm |
|
|
|
|
|
|
|
|
|