26electrolux

Fault Finding

Preliminary Electrical Systems Check

START

Isolate appliance and carry out:

A:Earth Continuity check.

 

 

 

YES

 

 

 

 

NO

Carry out:

 

 

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

Brown Blue Green

Yellow

Blue

Brown Green

Yellow

Carry out:

D:Resistance to Earth check.

NO

Inlet wiring

YES

Electricity supply

 

 

should now be

 

 

 

satisfactory.

 

 

 

 

 

 

PLUG (with cover removed)

S O C K E T

(face view)

faulty. Rectify any fault.

Earth Wire Green/Yellow

Neutral Wire Blue

(

)

 

FUSE

N

E()

L

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

Image 26
Contents Instruction booklet Page Welcome to the world of Electrolux Contents People Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hob Instructions for the User Lighting the burners OperationHob burners control knobs Only for models EHG 641, EHG 6412, EHGElectrolux Using the hob correctly Burner Minimum Maximum DiameterPan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements Provision for VentilationInstallation Gas Connection Location Fitting the Hob into the Worktop SealBuilding over a kitchen unit with door BuildingBuilding over a cupboard or drawer Electrical Connections This HOB Must be EarthedPermanent Connection Wiring diagram Fault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Minimum adjustment Pressure TestingProcedure CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions ExclusionsService and Spare Parts 0870 5 929European Guarantee Electrolux Page 35693-1702 10/07 R.A