Kenmore 119.16312800 manual How to Leak Test your LP Gas Tank For your safety, Regulator

Page 20

Notes about LP Gas Tank Exchange Programs

Many retailers that sell grills offer you the option of replacing your empty LP gas tank through an exchange service. Use only those reputable exchange companies that inspect, precision fill, test and certify their tanks. Exchange your tank only for an OPD safety feature equipped tank as described in the LP gas tank section of this manual.

Always keep new and exchanged LP gas tanks in an upright position during use, transit or storage.

Leak test new and exchanged LP gas tanks BEFORE connecting one to your grill.

How to Leak Test your LP Gas Tank

For your safety:

All leak tests must be repeated each time your LP gas tank is exchanged or refilled.

Do not smoke when checking for gas leaks.

Do not use an open flame to check for gas leaks.

Your grill must be leak tested outdoors in a well-ventilated area, away from ignition sources such as gas fired or electrical appliances. During the leak test, keep your grill away from open flames or sparks.

Do not use household cleaning agents as damage to gas assembly components can occur.

[] Use a clean paintbrush and a 50/50 mild soap and water solution.

FIBrush soapy solution onto the LP gas tank in the areas indicated by the arrows. See diagram.

FlIf growing bubbles appear do not use or move the LP Gas tank. Call an LP gas supplier or your fire department.

If growing bubbles appear do not use or move

the LP Gas tank. Contact an LP gas Supplier or

your fire department!

Regulator and LP Cylinder Connections

The gas pressure regulator provided with this outdoor cooking appliance must be used. This regulator is set for an outlet pressure of 11 inches water column.

Regulator:

Your regulator is equipped with a Q.C.C. Type 1 quick connect system. It will not allow gas to flow until a positive seal has been made. It has a thermal element that will shut off the gas flow if the temperature reaches 240 degrees F (115

degrees C). It also has a flow-limiting device that will restrict the flow of gas to 10 cubic feet per hour (0.28 cubic meters per hour).

TO CONNECT THE CYLINDER TO THE

REGULATOR AND HOSE

1.Be sure the LP cylinder is "OFF" by turning the hand wheel clockwise until it stops.

2.Place the cylinder into the base cabinet shelf of the grill with the valve facing outward and secure with the cylinder support ring.

3.Be sure all burner controls are turned to the "OFF" position.

4.Remove the safety cap from the cylinder valve.

5.Center the nipple of the regulator into the

cylinder valve.

6. Turn the black nut clockwise until it stops.

Hand Tighten Only, Do Not Use A Wrench,

Type i connection per

"', .............ANS Z21.58b-2006

,s

Quick

................ Coupling Nut

CAUTION: When the appliance is not in use the gas must be turned off at the tank.

20

Image 20
Contents Date of Purchase Liquid Propane Gas LPG GrillRecord Your Serial Number Kenmore 1-Year Full Warranty Limited Warranty on Selected Grill PartsHY-HOIE to arrange for Sears, Roebuck and Co Hoffman Estates, ILTheinstallationmustconformwithlocalcodesor PRE-ASSEMBLYPART# Part Description QTY Purpose of PartQty Part # SE0123D-002 Page KEY Description PART# QTY KEY Description PART# KEY Description PART# QTY Install Control Knobs and Casters HRemove Firebox from CabinetAttach Doors to Cabinet Cabinet Front Crossbar Door Top BracketsInstall Grease Tray Hang Condiment Basket and attach Cabinet Door StopInstall Grease Cup Bracket and Grease Cup AttachFireboxto CabinetInstall Towel Bar Handles, Utensil Hooks, Side Panels Side Burner Frame FireboxInstall Side Burner Valve Attach Side Burner Control Panel to Main Control PanelAttach Side Burner Control Knob WireInstall Side Shelf Frame to Firebox Install Heat Congratulations Assembly is now complete Correct LP GAS Tank USE Use your grill at least 2 feet away from anyHow to Leak Test your LP Gas Tank For your safety Regulator and LP Cylinder ConnectionsRegulator To Connect the Cylinder to Regulator and HoseDisconnecting a Liquid Propane Gas LPG Tank From Your Grill Flow Limiting Valves on LP Gas TanksTransportation and Storage Check all connections for LP Gas LeaksGrill Lighting Instructions Side Burner and Back Burner Lighting InstructionsManually Lighting the Burners with Match Holder Troubleshooting If the grill fails to light Follow the steps below to reset the flowPropercareandmaintenancewillkeepyourgrillin To reduce the chance of Flashback Fire you must Burner FlamesCooking Temperature An Important Note About Cooking TemperatureUsing the Back Burner If Equipped Burn-OffMy electronic ignition is not working Answer QuestionQuestion My grill will not light properly. Why? Answer Answer MY-HOME OurHome