Teledyne OT-2 operating instructions Section III Physical Hazards

Page 36

Appendix

Model OT-2 System

 

 

 

 

 

 

Section III – Physical Hazards

Potential for fire and explosion: The electrolyte in the Micro-Fuel Cells is not flammable. There are no fire or explosion hazards associated with Mi- cro-Fuel Cells.

Potential for reactivity: The sensors are stable under normal conditions of use. Avoid contact between the sensor electrolyte and strong acids.

Section IV – Health Hazard Data

Primary route of entry:

Ingestion, eye/skin contact

Exposure limits: OSHA PEL:

.05 mg./cu.m. (Pb)

ACGIH TLV:

2 mg./cu.m. (KOH)

Effects of overexposure

 

Ingestion:

The electrolyte could be harmful or fatal if

 

swallowed.

Eye:

Oral LD50 (RAT) = 3650 mg./kg

The electrolyte is corrosive; eye contact could

Dermal:

result in permanent loss of vision.

The electrolyte is corrosive; skin contact could

Inhalation:

result in a chemical burn.

Liquid inhalation is unlikely.

Signs/symptoms of exposure: Contact with skin or eyes will cause a burning sensation and/or feel soapy or slippery to touch.

Medical conditions

aggravated by exposure: None

Carcinogenicity: NTP Annual Report on Carcinogens: Not listed LARC Monographs: Not listed

OSHA: Not listed

Other health hazards: Lead is listed as a chemical known to the State of California to cause birth defects or other re- productive harm.

A-4

Teledyne Analytical Instruments

Image 36
Contents Model OT-2 Oxygen Transmitter System Model OT-2 System Copyright 1999 Teledyne Analytical InstrumentsTable of Contents Ground Model OT-2 System Introduction Introduction Model OT-2 System Front View Introduction Model OT-2 System Model OT-2 System Operational Theory IntroductionOperational Theory Model OT-2 System Micro-Fuel Cell Sensor Principles of OperationCross Section of a Micro-Fuel Cell not to scale Electrochemical Reactions Model OT-2 System Operational Theory Characteristic Input/Output Curve for a Micro-Fuel Cell Electronics and Signal Processing Sample Flow Description See Figure Piping Layout Operational Theory Model OT-2 System Installation Model OT-2 System OperationOperation Model OT-2 System Mounting DetailsGas Connections Operation Model OT-2 System Front View of Transmitter Operation Model OT-2 System Installing the Micro-Fuel Cell CalibrationSample System Component Locations Span Gas % F.S. x 4 + = Output in VDC 100 Testing the System 3 H2S ScrubberOperation Model OT-2 System Model OT-2 System Maintenance Model OT-2 System Scrubber Replacement Maintenance Model OT-2 System Appendix Qty Part Number Description Section I Product Identification Section III Physical Hazards Section V Emergency and First Aid Procedures Appendix