Teledyne 3000TA operating instructions ∙ Threshold Alarm

Page 35

Trace Oxygen Analyzer

Installation

 

 

 

Table 3-1: Analog Output Connections Pin Function

PinFunction

3+ Range ID, 4-20 mA, floating

4– Range ID, 4-20 mA, floating

5+ % Range, 4-20 mA, floating

6– % Range, 4-20 mA, floating

8+ Range ID, 0-1 VDC

23– Range ID, 0-1 VDC, negative ground

24+ % Range, 0-1 VDC

7– % Range, 0-1 VDC, negative ground

Alarm Relays: The nine alarm-circuit connector pins connect to the internal alarm relay contacts. Each set of three pins provides one set of Form C relay contacts. Each relay has both normally open and normally closed contact connections. The contact connections are shown in Table 3-2. They are capable of switching up to 3 amperes at 250 V ac into a resistive load. The connectors are:

Threshold Alarm 1:

Can be configured as high (actuates when concentration is above threshold), or low (actuates when concentration is below threshold).

Can be configured as failsafe or non-failsafe.

Can be configured as latching or non-latching.

Can be configured out (defeated).

Threshold Alarm 2:

Can be configured as high (actuates when concentration is above threshold), or low (actuates when concentration is below threshold).

Can be configured as failsafe or non-failsafe.

Can be configured as latching or non-latching.

Can be configured out (defeated).

System Alarm:

Actuates when DC power supplied to circuits is unacceptable in one or more parameters. Permanently

 

 

 

Teledyne Analytical Instruments

23

Image 35
Contents Teledyne Analytical Instruments Model 3000TACopyright 2011 Teledyne Analytical Instruments 3000TA- EUTrace Oxygen Analyzer Specific Model InformationImportant Notice Safety Messages 3000TA- EU Vii Table of Contents Operation MaintenanceAppendix Model 3000TA Front Panel List of FiguresList of Tables Typical Applications Main Features of the AnalyzerIntroduction OverviewIntroduction 3000TA- EU Model DesignationsModel 3000TA Front Panel Front Panel Operator InterfaceRecognizing Difference Between LCD & VFD ∙ 50-Pin Equipment Interface Port Rear Panel Equipment InterfaceIntroduction 3000TA- EU Trace Oxygen Analyzer Operational Theory Operational TheoryIntroduction Micro-Fuel Cell SensorAnatomy of a Micro-Fuel Cell Operational Theory 3000TA- EUElectrochemical Reactions Effect of Pressure Calibration CharacteristicsSample System Characteristic Input/Output Curve for a Micro-Fuel CellPiping Layout and Flow Diagram for Standard Model Flow Diagram Electronics and Signal Processing3000TA Internal Electronic Component Location Block Diagram of the Model 3000TA-EU Electronics Operational Theory 3000TA- EU Mounting the Analyzer InstallationTrace Oxygen Analyzer Installation Unpacking the AnalyzerFront Panel of the Model 3000TA Installation 3000TA- EUGas Connections Rear Panel ConnectionsSample Electrical Connections Exhaust OUTEquipment Interface Connector Pin Arrangement ∙ Threshold Alarm Alarm Relay Contact Pins Pin Function Range ID Relay Connections 2.3 RS-232 Port Remote Probe ConnectionsCommands via RS-232 Input Testing the System Installing the Micro-Fuel CellPage Trace Oxygen Analyzer Operation Using the Data Entry and Function ButtonsOperation Operation 3000TA- EU Hierarchy of Functions and Sub functions System FunctionTracking Oxygen Readings During Calibration and Alarm Delay TRAK/HLD Auto-Cal Pswd Logout More Setting up an Auto-Cal Password Protection A a a Characters Available for Password Definition Logout System Self-Diagnostic Test Showing Negative Oxygen Readings Version ScreenZero and Span Functions Zero Cal Zero Settling Man ENT To Begin Span Cal Span Val 000008.00 ENTSpan UPMod # #### % Span Slope=#### ppm/s Span Failure Alarms FunctionAL-1AL-2 Choose Alarm Range Function Setting the Analog Output Ranges Fixed Range Analysis Analyze Function Signal OutputMED Operation 3000TA- EU Teledyne Analytical Instruments Storing and Handling Replacement Cells MaintenanceRoutine Maintenance Trace Oxygen Analyzer MaintenanceRemoving the Micro-Fuel Cell Maintenance 3000TA- EUWhen to Replace a Cell Removing the Micro-Fuel Installing a New Micro-Fuel CellMaintenance 3000TA- EU Cell Warranty Fuse ReplacementInstalling Fuses System Self Diagnostic TestMajor Internal Components Troubleshooting CleaningTrace Oxygen Analyzer Maintenance Maintenance 3000TA- EU Teledyne Analytical Instruments Trace Oxygen Analyzer Appendix Model 3000TA SpecificationsAppendix Appendix 3000TA- EU Recommended 2-Year Spare Parts ListOrders should be sent to 19-inch Relay Rack Panel Mount Drawing ListFlow Rate Recommendations Application notes3000TA Examples Bypass Conversions Section II Physical and Chemical Data Material Safety Data SheetSection I Product Identification Section IV Health Hazard Data Appendix 3000TA- EU Section III -Physical HazardsSection VI Handling Information
Related manuals
Manual 19 pages 17.56 Kb

3000TA specifications

The Teledyne 3000TA is an advanced telemetry system designed for high-performance applications in various industries such as aerospace, automotive, and research. This innovative device combines cutting-edge technologies with user-friendly features, making it an essential tool for engineers and scientists alike.

One of the standout features of the Teledyne 3000TA is its robust data acquisition capabilities. It offers a high sampling rate, which allows users to capture rapid changes in measurements accurately. This is particularly beneficial for applications that require real-time data analysis and decision-making, such as testing the performance of new aircraft components or monitoring engine behavior under different loads.

The 3000TA integrates multiple sensor interfaces, enabling it to connect seamlessly with various types of sensors, including temperature, pressure, and strain gauges. This versatility makes it suitable for a wide range of testing scenarios, from structural analysis to environmental monitoring. Users can customize the system to fit their specific needs, significantly enhancing its functionality.

Another significant advantage of the Teledyne 3000TA is its advanced wireless communication technology. By employing protocols like Bluetooth and Wi-Fi, it allows for remote data monitoring and access, which improves safety and convenience during testing processes. Engineers can easily gather data from hazardous environments without being physically present, ensuring both efficiency and safety.

The device is also equipped with an intuitive user interface, which simplifies the setup and operation processes. The touchscreen display provides real-time data visualizations and easy navigation through various menus, making it accessible even to those new to telemetry systems. This user-centric design reduces the learning curve and enhances overall productivity.

In terms of data integrity, the Teledyne 3000TA features robust error-checking and validation protocols. These built-in safeguards ensure that the data collected is accurate and reliable, which is crucial for making informed decisions based on telemetry data.

The system's compact and lightweight design ensures portability, allowing for use in various fields and environments. This flexibility enhances its appeal for field applications, where space and weight can be significant constraints.

In summary, the Teledyne 3000TA stands out as a versatile and reliable telemetry solution, combining high-performance data acquisition, advanced communication technologies, and user-friendly features. Its application across multiple industries makes it an invaluable tool for professionals seeking to optimize their testing and analysis processes.