Agilent Technologies 54600-Series manual Agilent Passive Probes Selection Guide

Page 12

Probes

To get the most out of your scope, you need the right probes and accessories for your particular application. That's why Agilent Technologies offers a complete family of innovative probes and 54600-Series scopes. For more comprehensive information, please see the Agilent

54600-Series Oscilloscopes Probes and Accessories

data sheet (Agilent publication number 5968-8153). You can get a copy by calling 1-800-452-4844 or by visiting our website at: www.agilent.com/find/mso

Agilent Passive Probes Selection Guide

 

10070C

10073C (shipped

10074C (shipped

10076A

N2771A

 

 

with 54640-Series)

with 54620-Series)

high-voltage probe

high-voltage probe

 

 

 

 

 

 

Probe Bandwidth

20 MHz

500 MHz

150 MHz

250 MHz

50 MHz

 

 

 

 

 

 

Probe Risetime (Calculated)

< 17.5 ns

< 700 ps

< 2.33 ns

< 1.4 ns

< 7 ns

 

 

 

 

 

 

Attenuation Ratio

1:1

10:1

10:1

100:1

1000:1

 

 

 

 

 

 

Input Resistance

1 MΩ

2.2 MΩ

10 MΩ

66.7 MΩ

100 MΩ

(when terminated into 1 MΩ)

 

 

 

 

 

 

 

 

 

 

 

Input Capacitance

Approx. 70 pF

Approx. 12 pF

Approx. 15 pF

Approx. 3 pF

Approx. 1 pF

 

 

 

 

 

 

Maximum Input

400 Vpk CAT I

500 Vpk CAT I

500 Vpk CAT I

4000 Vpk

15 kV dc, 10 kVrms

(dc + peak ac)

(mains isolated)

(mains isolated)

(mains isolated)

 

30 kV dc + peak ac

 

400 Vpk CAT II

400 Vpk CAT II

400 Vpk CAT II

 

 

 

(post receptacle

(post receptacle

(post receptacle

 

 

 

mains)

mains)

mains)

 

 

 

 

 

 

 

 

Compensation Range

None

6 - 15 pF

9 - 17 pF

6 - 20 pF

7 - 25 pF

 

 

 

 

 

 

Probe Sense

No

Yes

Yes

Yes

No

 

 

 

 

 

 

Current Probes

Description

 

 

1146A

100 kHz current probe, ac/dc

 

 

N2774A

50 MHz current probe, ac/dc

 

 

N2775A

power supply for N2774A

 

 

Differential Probes

Description

 

 

N2772A

20 MHz differential probe

 

 

N2773A

Differential probe power supply

 

 

12

Image 12
Contents Ideal for mixed analog and digital analysis 60 to 500 MHz, up to 2 GSa/sMB to 8 MB MegaZoom deep memory standard Selection Guide Selection GuideModel Maximum Sample Rate Maximum Memory ChannelsChannel scope model 54624A Affordable and Responsive MegaZoom deep memoryStandard features Connectivity made easierBuilt-in floppy drive Built-in help at your fingertipsOther standard features Deep memory transfer over the busN2758A can Trigger Module Triggering Flexible TriggeringCAN, LIN, and USB Triggering I2C and SPI Triggering Microcontroller DSP ApplicationsCapture all of your data at once Standard Serial Triggering Probes Agilent Passive Probes Selection GuidePerformance Characteristics Acquisition Analog ChannelsVertical System Analog Channels 54641A/D, 54642A/DDC to max bandwidth 40 dB Horizontal Same Channel Example 54641A/D, 54642A/DTrigger System Pulse WidthI2C External EXT TriggeringMeasurement Features Display SystemGeneral Characteristics StoragePower Requirements OtherOrdering Information Warranty and Calibration Options Accessories DescriptionAvailable Options Description Passive Probes DescriptionLogic Probes Description Active probes DescriptionCables Description 5968-8152EN