About the Controls on the Air Conditioner

Additional controls and important information.

Ventilation

The ventilation lever must be in the CLOSE position in order to maintain the best

 

cooling conditions. When fresh air is necessary in the room, set the ventilation

 

lever to the OPEN position.

 

 

The damper is opened and room air is drawn out.

CLOSE VENT OPEN

 

NOTE: Before using the ventilation feature, and prior to installing the front grille,

 

Part B

 

 

pull down part until level with part .

 

Part A

Air Direction

The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and the vertical louver.

VERTICAL AIR-DIRECTION CONTROL HORIZONTAL AIR-DIRECTION CONTROL

Controlled

Controlled

Controlled by Remote

manually

manually

Controller (Model: CW-XC84HU)

The vertical air direction is adjusted by

The horizontal air direction is adjusted by rotating

rotating the horizontal louver forward or

the vertical louver right or left manually or by

backward manually.

Remote Controller.

How to Secure the Drain Pipe

In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. Press the drain pipe into the hole by pushing down and away from the fins to avoid injury.(See Fig.1)

Optional(CW3H02502C)

1.Remove the rubber plug and slide the chassis out from the cabinet.(See Fig.2)

2.Install the drain pan over the corner of the cabinet where you removed the plug with 4 (or 2) screws.(See Fig.3)

3.Connect the drain hose to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied).(See Fig.3)

4.Select the most appropriate connection from among the figures to the right (by considering the hole of the unit) to fit drain pan to your own unit.(See Fig.3)

5.Slide the chassis back into the cabinet. Reinstall the cabinet screws. Secure the cabinet to chassis by using screws. (See Fig.4)

Drain pipe

 

 

Drain cap

Fig. 1

Remove the

 

 

rubber plug

 

Fig. 2

CABINET

 

 

DRAIN

DRAIN HOSE

 

Inside diameter 17mm (5/8")

PAN

 

 

 

SCREW

Fig. 3

 

 

 

 

Fig. 4

8

Image 8
Contents Manuel Dinstallation ET Dutilisation Au Canada Pour de laide, composez leSafety Precautions Care and MaintenanceFeatures Before you call for ServiceSafety Precautions Meanings of symbols used in this manual are as shown belowPlug in the power plug properly Do not modify power cord Do not operate with wetVentilate well when used Do not operate switchesTogether with a stove, etc With wet handsAbout the Controls on the Air Conditioner ControlsFor Normal Cooling For Maximum CoolingTemperature Setting ON/OFF TimerOperation ModeDRY Remote controllerAIR Swing How to Secure the Drain Pipe VentilationAir Direction Additional controls and important informationHow to Insert Batteries Care and MaintenanceAir Filter Cleaning Features FeaturesHow to Install the Unit Window RequirementsInstallation Kit Contents Suggested Tool Requirements Cabinet Installation Bottom PAN Electrical Data USE of Extension CordsElectrical Data USE of Extension Cords Electrical Safety Applies to USA and Puerto RicoSituations Where the Appliance will be Disconnected Often Abnormal Operation Before you call for serviceNormal Operation Model CW-C84GU HotMemo Instructions pour ’installation Avant de placer un Appel de serviceMesures de sécurité Instructions de FonctionnementMesures de sécurité Votre appareilNe faites pas fonctionner Lappareil les mains Mouillées Ne pas diriger lair froid Directement sur les PersonnesNe pas nettoyer le Climatiseur à grande eau Ne pas se servir de lappareil Des fins spécialesLes commandes Instructions de fonctionnementPour UN Refroidissement Normal Pour UN Refroidissement MaximalAlimentation REFROIDISSEMENT/VENTILATEURMinuterie MARCHE/ARRÊT Réglage DE LA TempératureTélécommande Mode SECHeures → 11 heures → 12 heures → Ce bouton peut contrôler automatiquement laLa ventilation Ajuster la direction dairComment utiliser le tuyau d’évacuation Facultatif CW3H02502CNettoyage et entretien Nettoyage du filtre à airComment insérer les piles Remettez le couvercle dans sa glissièreCaractéristiques CaractéristiquesConditions requises pour linstallation à la fenêtre Instructions pour linstallationChoisissez le meilleur emplacement Préparatifs DU Châssis Contenu de lensemble dinstallationOutils requis pour l’installation Les vis Type B à travers langle frontal, dans le rebord Installation du boîtierRemarque Mise EN Garde NE Percez PAS UN Trou AU Données sur lélectricité Utilisation DE Cordons ProlongateursLutilisation DE Cordons Prolongateurs Situations OÙ Lappareil Naura PAS À Être Débranché SouventSituations OÙ Lappareil Devra Être Débranché Fréquemment Fonctionnement anormal Avant de placer un appel de serviceFonctionnement normal Modèle CW-C84GU Le climatiseurMemo Precauciones Importantes de Seguridad Instrucciones de FuncionamientoCaracterísticas Instrucciones de InstalaciónConecte correctamente el Enchufle No opere o pare la unidad insertando o tirando del enchufeNo dañe o utilize un cable Eléctrico inadecuado No lo maneje con las manos HumedasNo lo utilice para propósitos Especiales No manipule los Interruptores con las manos MojadasInstruccionnes de Funcionamiento ControlesPara UN Enfriamiento Normal Para UN Enfriamiento MaximoENECNDIDO/APAGADO FRÍO/VENTILADORVelocidad DEL Ventilador Ajuste DE LA TemperaturaControl remoto Ahorrador DE EnergíaComo Installar el Tubo de Desagüe VentilaciónComo controlar la direccion del aire Controles adicionales e informacion importanteCómo poner las baterías Cuidado y MantenimientoLimpieza de filtro de Aire Características CaracterísticasInstrucciones de Instalación Elija el major lugarRequistios de ventana La parte superior e inferiro de la ventanaContenido del Juego de Instalación Requisitos de las herra mientas sugeridasPreparacion DEL Chasis Sujete el armazon a la unidad con 4 tornillos. Tipo aInstalación del Gabinete NotaCaracterísticas Datos Electricos Utilice el enchufe de la paredStandard 125V, enchufe de Puntas para enchufarInformacion Electrica Aplica a USA y Puerto Rico USO DE ExtensionesOperación anormal Antes de avisar al Servicio TécnicoOperación normal Modelo CW-C84GU Memo Phase ModelModèle ModeloCW-C84GU Ref Acwar 11/03 Ref. AcwarFr 11/03 Panasonic Room Air Conditioner