Panasonic CU-2S18NBU-1 Safety Precautions, Items to be followed are classified by the symbols

Page 3

1. Safety Precautions

Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.

Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed.

The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.

WARNING

CAUTION

This indication shows the possibility of causing death or serious injury.

This indication shows the possibility of causing injury or damage to properties.

The items to be followed are classified by the symbols:

This symbol denotes item that is PROHIBITED from doing.

Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.

WARNING

1.Do not modify the machine, part, material during repairing service.

2.If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit.

3.Do not wrench the fasten terminal. Pull it out or insert it straightly.

4.Engage authorized dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage, electrical shock or fire.

5.Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire.

6.Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock.

7.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury.

8.For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.

9.This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown.

Do not use joint cable for indoor / outdoor connection cable. Use specified indoor / outdoor connection cable, refer to Installation

10.Instructions CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the connection.

11.Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock.

12.When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigerant cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).

13.Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb up to outdoor unit and cross over the handrail and causing accident.

14.This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.

15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.

16.Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.

17.Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.

For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials.

18.Thickness of copper pipes used with R410A must be more than 0.8mm (1/32”). Never use copper pipes thinner than 0.8mm (1/32”).

It is desirable that the amount of residual oil is less than 40 mg/10m (0.0008 oz/ft).

During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration

19.piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).

3

Image 3
Contents Table of Contents Disassembly and Assembly Instructions Items to be followed are classified by the symbols Safety PrecautionsPage Model Outdoor Unit CU-2S18NBU-1 SpecificationMulti split combination possibility Dimensions Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Electronic Circuit Diagram Main Printed Circuit Board Printed Circuit BoardNoise Filter Printed Circuit Board Check Points Installation InformationOutdoor Unit Installation Diagram Installation InstructionOutdoor Unit Installation Guidelines Gas Leak Checking Connecting the Piping to Outdoor UnitEvacuation of the Equipment Heat Insulation Outdoor fan control Powerful OperationOperation Control Cooling OperationFreeze Prevention control Cool Electronic Parts Temperature Rise Protection 1 CoolElectronic Parts Temperature Rise Protection 2 Cool Protection Control12.7 30 seconds Force Operation Time Delay Safety Control Restart ControlIPM power transistor Protection Control Cooling overload control CoolCompressor Protection Control Gas leak detection control Valve close detection controlCompressor discharge high pressure protection control Test Operation Servicing ModeWiring Error Check Pump Down OperationMode priority function Power Save ModeSelf Diagnosis Function Troubleshooting GuideIndoor high Check indoor heat Exchanger Remove the Control Board Cover and Particular Plates Disassembly and Assembly InstructionsOutdoor Unit Removal Procedure Removing the Cabinet Top Plate and Cabinet Front PlateRemoving the Propeller Fan and Fan Motor Removing the Control P.C. BoardPage Technical Data Operation CharacteristicsCS-S9NKUW-1 CU-2S18NBU-1 Page CS-S9NKUW-1x2 CU-2S18NBU-1 Page CS-S12NKUW-1 CU-2S18NBU-1 Page CS-S12NKUW-1x2 CU-2S18NBU-1 Page CS-S12NKUW-1+CS-S9NKUW-1 CU-2S18NBU-1 Page Exploded View and Replacement Parts List REF. no Description & Name QTY Shock Absorber Left