SECTION 
TROUBLESHOOTING GUIDE
SYMPTOM | PROBABLE CAUSE | SOLUTIONS | 
  | 
  | 
  | 
Erratic performance of  | Low tire pressure.  | Inflate tires to the proper tire pressure.  | 
wheelchair (driving uphill,  | 
  | 
  | 
increase in braking distance).  | 
  | 
  | 
  | 
  | 
  | 
Wheelchair will not drive.  | Low tire pressure.  | Inflate tires to the proper tire pressure.  | 
  | Motor engagement handles  | Engage motor engagement handles.  | 
  | are disengaged.  | 
  | 
  | Batteries require charging.  | Charge batteries. Make sure the setting on the  | 
  | 
  | charger is correct.  | 
  | Charger plugged in.  | Unplug charger from wall outlet before operat-  | 
  | 
  | ing the wheelchair.  | 
  | Circuit breaker tripped.  | Press the reset button. Refer to Resetting the  | 
  | 
  | Circuit Breaker on page 28.  | 
  | 
  | 
  | 
Batteries draw excessive  | Battery failure.  | Have batteries checked for shorted cell. Replace  | 
current when charging.  | 
  | if necessary.  | 
  | Electrical malfunction.  | Contact Dealer/Invacare.  | 
  | 
  | 
  | 
Battery indicator shows low  | Batteries weak, won’t hold  | Replace Batteries.  | 
charge level immediately  | charge.  | 
  | 
after charging.  | 
  | 
  | 
  | Electrical malfunction.  | Contact Dealer/Invacare.  | 
  | Charger malfunction.  | Replace charger. Contact Dealer/Invacare.  | 
  | 
  | 
  | 
Motor “chatters” or runs  | Electrical malfunction.  | Contact Dealer/Invacare.  | 
irregularly.  | 
  | 
  | 
  | 
  | 
  | 
Only one (1) drive wheel  | Electrical malfunction.  | Contact Dealer/Invacare for service.  | 
turns.  | 
  | 
  | 
  | One (1) motor is disen-  | Engage motor engagement handle.  | 
  | gaged.  | 
  | 
  | 
  | 
  | 
Joystick erratic or does not  | Electrical malfunction.  | Contact Dealer/Invacare for service.  | 
respond as desired.  | 
  | 
  | 
  | Controller programmed  | Reprogram controller (Refer to electronics man-  | 
  | improperly.  | ual supplied with wheelchair).  | 
  | 
  | 
  | 
Wheelchair does not  | Poor battery terminal con-  | Have terminals cleaned.  | 
respond to commands.  | nection.  | 
  | 
  | 
  | 
  | 
Power indicator off - even  | Electrical malfunction.  | Contact Dealer/Invacare for service.  | 
after recharging.  | 
  | 
  | 
  | 
  | 
  | 
NOTE: For additional troubleshooting information and explanation of error codes, refer to the Electronics Manual supplied with each wheelchair.