Omega OSP SERIES manual Specifications, Thermocouple measuring ranges

Page 8

1.2Specifications

Target dimensions at different distances

Nominal target diameter at 95% energy

Temperature measuring ranges: -30 to 2000°C (-22 to 3632°F)

Thermocouple measuring ranges:

type K : -100°C to +1370°C (-148 to 2500°F) 0.1°C resolution

type S : 0°C to +1760°C (-32 to 3200°F) 0.1°C resolution

Spectral response:

OSP 500, 800 & 1000 : 8 - 14 µm

OSP 1300 : 1.6 µm

OSP 1600 & 2000 0.9 µm

Accuracy:

OSP 500, 800 & 1000: ±(1% of the reading +1°C/2°F)

OSP 1300, 1600 & 2000: ±(0.5% of the reading +1°C/2°F)

Repeatability IR:

OSP 500, P800 & P1000 : ±0.5% of the reading

OSP 1300, P1600 & P2000: ±0.25% of the reading

Temperature stability IR:

for the band exceeding +18°C to +28°C: ±0.01% of f.s./°C

Display:

High contrast custom LCD with backlight device

Display resolution:

1°C / °F / K (0.1°C/0.1°F in AVG mode up to 200°C)

Alarms:

Acoustic and visible

Measurement sampling time: <300 ms

Emissivity:

Adjustable from 0.10 to 1.00 in 0.01 steps

Analog output:

1mV/ °C/ °F/ K

Digital interface:

full bi-directional TTL level port Optional TTL to RS232 adapter

Calculated functions: Hold, average, max, min, T

Data memory:

500input data structured by tag

Calibration:

self learning technique with automatic procedure

Laser:

Wavelength: 650nm

Maximum optical power: <1mW

FDA Classification: Class II, Complies with 21CFR Chapter 1, Subchapter J

Safety classification: Class 2

Beam diameter: 3mm

Beam divergence: <0.5mrad

Laser indicator: asterisk on display

Power supply:

alkaline or rechargeable type AA battery

Battery life:

16h (with backlight off)

Battery low level of charge: symbol on the LCD display

Line operation:

100, 115, 230 Vac through the external charger

Charger transformer insulation:

2500 V

Battery recharging time:

8h at 90% (instrument switched off)

Operating environment temperature range: from -10°C to +55°C (-14 to 131°F)

Storage temperature range:

from -30 °C to +60 °C (-22 to 140°F) without battery

Case:

Injection moulded ABS+ policarbonate

Dimensions:

200x 180 x 80 mm (7.87 x 7.09 x 3.15”)

Weights:

net 0.8 kg (1.76 lb); gross 1.5 kg (3.3 lb)

8

Image 8
Contents OSP Series Portable IR thermometers OMEGAnetSM On-Line Service Internet e-mail Info@omega.com Introductory Note Table of Contents Data Acquisition Operative Mode Innovative design General featuresGeneral Description Instrument codes Specifications Thermocouple measuring rangesGeneral Features GeneralOptical System Target pinpointingKeyboard DisplayDigital Interface Self calibrationLogging Mode Calculated MeasurementsCase Logging Data ManagerPhysical Description Power supply Functional DescriptionFirmware Battery chargerMicrocontroller Unpacking PRE-OPERATIONAL Check ΛEM = 10.6 ∝MPower Supply How to maximize the life span of the batteryPower supply with alkaline batteries Power supply from main line ACLaser Sight Analogue inputPage How to Operate the instrument OperationsQuick Start Trigger * MEM SEL EnterHold Laser sightingUnstable temperature measurement Working band WeightAlarm settings HAL Minimum, maximum, average and difference indication Automatic Emissivity Setting Configuration Thermocouple input enabledTemperature Scale selection Technical Unit selectionDate & Real Time clock setting Acquisition settingsAmbient Temperature Compensation TAM Buzzer On/OffOSP 500/800 decimal point selection Actual Target Emissivity Ambient Temp Indicated Temp TAMFirmware revision number Instrument serial numberBattery level of charge Acquisition by dedicated Tags Data Acquisition Operative ModeHow to operate in data acquisition mode Log Recall stored data Program Architecture InstallationLogging Data Manager File HelpData EditToolbars Quick starting Copy into an open fileMove into a new file Move into an open filePress the or key to select the Tag a identification code Log Page Sighting telescope system Options & AccessoriesPrinter operations Filter installation Installation of the sighting deviceRed Point pinpointing system Part n DescriptionPage Application Notes Infrared energyApplications EmissivityTTL to RS 232 adapter Digital output wiring practiceDigital Interface Computer Communication protocolComputer data request from OSP to PC $00 Pyrometer measure Reading valuesComputer data setting from PC to OSP Writing valuesCommunication programs Example a Data transfer from OSP to PCExample B PC instructions to OSP Example aExample B 9Ø Chksum = DATA1 + DATA2 + DATA3 + DATA4 and &H7FMaintenance Faulty operating conditionsStorage ErrAppendix A1 How to determine an object emissivity A1.1 Typical Emissivity ValuesA1.2 Metals Typical Emissivity Values 14 µmA1.3 Non-metals Typical Emissivity Values Index Weight Working band WARRANTY/DISCLAIMER Temperature