Omega OSP SERIES manual Press the or key to select the Tag a identification code

Page 39

"Select <OK> button to save the preference setting in the PC Memory.

"From the preference menu you can also set the header and footer line as you need for later printed report.

"Save model (Save as …) with extension .LMM.

"Now connect the instrument with the communication cable and turn it on.

"Open the file AGC.LMM (if previously closed ).

"Select the <Data> command from the menu and then the option <Save Tag>. Select for example Tag A and press the <Ok> button.

"Disconnect the unit and go on the field to take same measurements (see also cap.10 to operate in an acquisition mode).

"Start this procedure with the OSP switched -Off-

"Keep the <MEM> key pressed and, simultaneously, press the <Trigger> until the following indication is displayed :

Log

°C

Lock

e

Press the <▲> or <▼> key to select the Tag A identification code.

Log

°C

Lock

e

Press the <SEL> key to display the number of memory locations still available.

Log

°C

Lock

e

Data can be recorded in the selected Tag in manual or automatic mode. About the acquisition mode and setting of time acquisition, refer to par. 9.5.

If necessary, press the <SEL> key to obtain the page that allows the clearing of the previous memory stored data in the Tag A:

39

Image 39
Contents OSP Series Portable IR thermometers OMEGAnetSM On-Line Service Internet e-mail Info@omega.com Introductory Note Table of Contents Data Acquisition Operative Mode General features General DescriptionInnovative design Instrument codes Thermocouple measuring ranges SpecificationsTarget pinpointing General FeaturesGeneral Optical SystemSelf calibration KeyboardDisplay Digital InterfaceLogging Data Manager Logging ModeCalculated Measurements CasePhysical Description Functional Description Power supplyBattery charger MicrocontrollerFirmware Unpacking ΛEM = 10.6 ∝M PRE-OPERATIONAL CheckPower supply from main line AC Power SupplyHow to maximize the life span of the battery Power supply with alkaline batteriesAnalogue input Laser SightPage Trigger * MEM SEL Enter How to Operate the instrumentOperations Quick StartLaser sighting HoldWorking band Weight Unstable temperature measurementAlarm settings HAL Minimum, maximum, average and difference indication Automatic Emissivity Setting Technical Unit selection ConfigurationThermocouple input enabled Temperature Scale selectionAcquisition settings Date & Real Time clock settingActual Target Emissivity Ambient Temp Indicated Temp TAM Ambient Temperature Compensation TAMBuzzer On/Off OSP 500/800 decimal point selectionInstrument serial number Firmware revision numberBattery level of charge Data Acquisition Operative Mode How to operate in data acquisition modeAcquisition by dedicated Tags Log Recall stored data Installation Logging Data ManagerProgram Architecture Edit FileHelp DataToolbars Move into an open file Quick startingCopy into an open file Move into a new filePress the or key to select the Tag a identification code Log Page Options & Accessories Printer operationsSighting telescope system Part n Description Filter installationInstallation of the sighting device Red Point pinpointing systemPage Emissivity Application NotesInfrared energy ApplicationsDigital output wiring practice Digital InterfaceTTL to RS 232 adapter Communication protocol Computer data request from OSP to PCComputer Reading values $00 Pyrometer measureWriting values Computer data setting from PC to OSPExample a Communication programsExample a Data transfer from OSP to PC Example B PC instructions to OSP9Ø Chksum = DATA1 + DATA2 + DATA3 + DATA4 and &H7F Example BErr MaintenanceFaulty operating conditions StorageAppendix A1.1 Typical Emissivity Values A1 How to determine an object emissivity14 µm A1.2 Metals Typical Emissivity ValuesA1.3 Non-metals Typical Emissivity Values Index Weight Working band WARRANTY/DISCLAIMER Temperature