MaxTech OM-25ME operating instructions Preface

Page 4

PREFACE

This manual describes the function, operation and maintenance of the Maxtec Model OM-25ME and OM-25ME-L oxygen monitors. Notes are included where differences may occur between the two monitors. As members of Maxtec's MAXO2 line of oxygen analyzers and monitors, the OM-25ME utilizes the Maxtec MAX-250E oxygen sensor and is engineered for fast response, maximum reliability and stable performance. The OM-25ME is designed primarily for continuous monitoring of oxygen levels delivered by medical oxygen delivery equipment and respiratory care systems. Adjustable high and low level alarm setpoints make the OM-25ME ideal for use in neo-natal, anesthesia, and respiratory care.

THANK YOU

Thank you for your purchase of a Maxtec MAXO2 oxygen monitor. We appreciate the time and energy you invest in selecting the equipment best suited to your needs. As repayment, we are supplying you with a reliable, high-quality instrument that, with proper care and operation, will provide you with years of exceptional service. We also encourage your comments or suggestions as to how our equipment, in any way, can better serve your needs. Please feel free to write, FAX or e-mail us at the address on the back of this manual c/o the Maxtec Marketing Department.

NOTE: In order to obtain optimum performance from your MAXO2 monitor, all operation and maintenance must be performed in accordance with this manual. Please read the manual thoroughly before using the monitor and do not attempt any repair or procedure that is not described herein. Maxtec cannot warrant any damage resulting from misuse, unauthorized repair or improper maintenance of the instrument.

!WARNING

The sensor of the MAXO2 Oxygen Monitor (MAXO2) has been tested with various anesthesia gases including Nitrous oxide, Halothane, Isoflurane, Enflurane, Sevoflurane and Desflurane and found to have acceptable low interferance, the device in its entirety (including electronics) is not suitable for use in the presense of a flammable anesthetic mixture. Only the threaded sensor face, flow diverter, and “T” adapter may be allowed to contact such a gas mixture.

ii

Image 4
Contents Model OM-25ME Page Page Preface Iii Page SET-UP Procedure Base Unit Specifications Sensor SpecificationsBase Unit Description Components Description please refer to LCD ReadoutLCD Readout Alarm LEDs Keypad External ProbeAlarm LEDs External Probe MAX-250E Oxygen Sensor Battery Installation Calibrating the MAXO2 Monitor Before You BeginTo Calibrate the MAXO2 Monitor Automatic Calibration to Room Air Effects of Temperature Pressure Effect Humidity EffectAlarm Setting Procedure Low Alarm Setting Basic Operation Sensor Removal and Replacement Problem Solving Base Unit Specifications Exposure to Anesthetic Gases Calibration Techniques in Pressurized SystemsCalibration Errors Page Spare Parts and Accessories Warranty Page Email sales@maxtecinc.com