Toshiba LF410/LF602, LF410/LF600 Ordering Information, About establishment environment

Page 13

LF410/LF600 LF410/LF602

About establishment environment

Do not store or install the flowmeter in:

Places where there is direct sunlight.

Places where excessive vibration or mechanical shock occurs.

Places where high temperature or high humidity conditions obtain.

Places where corrosive atmospheres obtain.

Places submerged under water.

Place where there is slop floor. To put the flowmeter temporarily on the floor, place it carefully with something, such as stopper, to support it so that the flowmeter will not topple over.

In places like the following places, there is the case that infrared switches do not function correctly. (If this is unavoidable, use an appropriate cover.

•Places where gets very bright light onto operation panel. (direct sunlight, reflection light of sunlight by windowpanes, diffused reflection light of strength etc.)

•Places where smoke and steam occur near.

•Places where a snow, ice or mud that may attached.

Ordering Information

1.When ordering the LF410 series flowmeters, refer to Tables 3 and 4 (Type Specification Codes). An entry must be made for each of the columns in each of these tables.

2.Fluid characteristics:

(1)Type of fluid to be measured and its characteristics

(2)Fluid temperature

(3)Fluid pressure

(4)Electrical conductivity of the fluid

3.Measuring range

4.I/O function setting

5.Ordering scope:

Flow calibration data: (required or not)

6.Other items

Specifications other than standard items

Consult Toshiba representative before ordering when choose materials of the wetting parts such as lining, electrodes, and grounding rings.

13

Image 13
Contents Measurement range in terms of flow velocity Overall SpecificationsModel LF600 and LF602 converters Model LF410 and LF414 DetectorsDigital output DO2 opt Digital output DO1 stdCommunications output : HARTstd Vibration resistance Cable connection ports Cable glandsDimensions InstallationSeparate type detectors LF410 and LF414 Meter size 15mm 1/2 Separate type detectors LF410 and LF414 Meter size 25mm Combined type LF410/LF600 and LF414/LF600 flowmeters External ConnectionsSeparate type LF410/LF602 and LF414/LF602 flowmeters Wiring Precautions Profibus Wiring PrecautionsGrounding of the Combined type and Separate type Piping PrecautionsTo select the meter size Meter SizeCalibration Range PED matrix in each flange connectionAbout establishment environment Ordering InformationSpecification Code Wafer type detector LF410 Series Specification Code for converters ISO9001 and ISO14001 are certified