LF410/LF600 LF410/LF602
Table 3. Specification Code (Wafer type detector LF410 Series)
| Model |
|
|
|
| Specification Code | Description |
| Detector category |
| ||||||
|
|
|
|
| Normal type | Ex. type | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
1 | 2 | 3 |
| 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 12 13 14 |
| ||||
L | F | 4 |
| 1 | 0 |
|
|
|
|
|
| Normal specification type | √ | √ | √ | √ |
L | F | 4 |
| 1 | 4 |
|
|
|
|
|
| Hazardous location certification type (Note 1) |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| Meter size | √ |
| √ |
|
|
|
|
|
|
| D |
|
|
|
|
| 15mm (½") |
|
| ||
|
|
|
|
|
| E |
|
|
|
|
| 25mm (1") | √ |
| √ |
|
|
|
|
|
|
| F |
|
|
|
|
| 40mm (1½") | √ |
| √ |
|
|
|
|
|
|
| G |
|
|
|
|
| 50mm (2") | √ |
| √ |
|
|
|
|
|
|
| H |
|
|
|
|
| 80mm (3") | √ |
| √ |
|
|
|
|
|
|
| J |
|
|
|
|
| 100mm (4") | √ | √ | √ | √ |
|
|
|
|
|
| K |
|
|
|
|
| 150mm (6") |
|
| ||
|
|
|
|
|
| L |
|
|
|
|
| 200mm (8") |
| √ |
| √ |
|
|
|
|
|
|
|
|
|
|
|
| Mounting Style | √ | √ |
|
|
|
|
|
|
|
|
| L |
|
|
|
| Detector/Converter combined type (LF410/LF600) |
|
| ||
|
|
|
|
|
|
| M |
|
|
|
| Detector/Converter separate type (LF410/LF602) | √ | √ |
|
|
|
|
|
|
|
|
| P |
|
|
|
| Detector/Converter combined type with PED (LF410/LF600) (Note 6) | √ | √ |
|
|
|
|
|
|
|
|
| Q |
|
|
|
| Detector/Converter separate type with PED (LF410/LF602) (Note 6) | √ | √ |
|
|
|
|
|
|
|
|
|
|
|
|
|
| FM and CSA Class - I Division 2 type (Note 1) |
|
| √ | √ |
|
|
|
|
|
|
| A |
|
|
|
| Detector/Converter combined type (LF414/LF600) |
|
| ||
|
|
|
|
|
|
| B |
|
|
|
| Detector/Converter separate type (LF414/LF602) |
|
| √ | √ |
|
|
|
|
|
|
|
|
|
|
|
| Connection flange standard (Note 2) |
|
|
|
|
|
|
|
|
|
|
|
| C |
|
|
| ANSI 150 |
|
|
|
|
|
|
|
|
|
|
|
| D |
|
|
| ANSI 300 |
|
|
|
|
|
|
|
|
|
|
|
| E |
|
|
| BS PN 10 |
|
|
|
|
|
|
|
|
|
|
|
| F |
|
|
| BS PN 16 |
|
|
|
|
|
|
|
|
|
|
|
| G |
|
|
| DIN PN 10 |
|
|
|
|
|
|
|
|
|
|
|
| H |
|
|
| DIN PN 16 |
|
|
|
|
|
|
|
|
|
|
|
| J |
|
|
| JIS 10K |
|
|
|
|
|
|
|
|
|
|
|
| K |
|
|
| JIS 16K |
|
|
|
|
|
|
|
|
|
|
|
| L |
|
|
| JIS 20K |
|
|
|
|
|
|
|
|
|
|
|
| Z |
|
|
| other |
|
| – | – |
|
|
|
|
|
|
|
|
|
|
|
| Electrode Material (Note 6) |
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
| 316L stainless steel |
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
| Ti (titanium) |
|
|
|
|
|
|
|
|
|
|
|
|
| D |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| E |
|
| Ta (tantalum) |
|
|
|
|
|
|
|
|
|
|
|
|
| F |
|
| Hastelloy C (Equivalent) |
|
|
|
|
|
|
|
|
|
|
|
|
| Z |
|
| other |
|
| – | – |
|
|
|
|
|
|
|
|
|
|
|
| Lining Material (Note 6) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
| – |
| – | |
|
|
|
|
|
|
|
|
|
| B |
|
| – |
| – | |
|
|
|
|
|
|
|
|
|
| C |
| Teflon PFA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Grounding Ring Material (Note 6) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C | 316 stainless steel |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D | 316L stainless steel |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E | Ti (titanium) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F | Ta (tantalum) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| G |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| H | Hastelloy C (Equivalent) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Z | other |
|
| – | – |
Flow and calibration velocity range
A0.3 to 10 m/s (standard range calibration)
B0.3 to 10 m/s (specified range calibration)
C0.1 to 10 m/s (specified range calibration)
Excitation and Signal Cables
Anot provided
B30m cable, provided (Note 4)
Cother lengths, provided (Note 4)
Coating |
|
|
A no coating | – | – |
Bphthalic acid resin coating
Cblack tar epoxy resin 0.3 mm
Dblack tar epoxy resin 0.5 mm
EBlack tar epoxy resin 0.5 mm for submersible type (Note 7)
Size code explanation: √ :Object | : Standard | : Option |
Note1: Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter.
Note2: Same shape of flange standard among ANSI 150, ANSI 300, BS10, BS16, DIN10, DIN16, JIS10K, JIS16K, and JIS20K.
Note3: The type of material used is alumina ceramic, this is suitable for both acid and alkali liquids.
This ceramic lining and the electrodes are held with seals, there are two types, one for acids, and the other for alkalis. Note4: Separate type detector only. Specifyng the code “C”, indicate the length of cables from 1 to 300m in 1 meter increments. Note5: Phthalic acid resin coating is standard for the flowmeter with meter size 15mm(1/2”), 150mm(6”), and 200mm(8”). Note6: Consult Toshiba before ordering when choose materials at the wetting parts.
Note7: Ceramic lining only. (Teflon PFA lining is not available.)
Note8: Check the Table 2 whether your chosen meter size meets this directive or not when the meter is shipped to EU. If yes, need to choose this code.
14