Toshiba LF410/LF600, LF410/LF602 specifications Specification Code Wafer type detector LF410 Series

Page 14

LF410/LF600 LF410/LF602

Table 3. Specification Code (Wafer type detector LF410 Series)

 

Model

 

 

 

 

Specification Code

Description

 

Detector category

 

 

 

 

 

 

Normal type

Ex. type

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

4

5

6

7

8

9

10

11 12 13 14

 

Gr.-A

Gr.-B

Gr.-C

Gr.-D

L

F

4

 

1

0

 

 

 

 

 

 

Normal specification type

L

F

4

 

1

4

 

 

 

 

 

 

Hazardous location certification type (Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Meter size

 

 

 

 

 

 

 

 

D

 

 

 

 

 

15mm (½")

 

 

 

 

 

 

 

 

E

 

 

 

 

 

25mm (1")

 

 

 

 

 

 

 

 

F

 

 

 

 

 

40mm (1½")

 

 

 

 

 

 

 

 

G

 

 

 

 

 

50mm (2")

 

 

 

 

 

 

 

 

H

 

 

 

 

 

80mm (3")

 

 

 

 

 

 

 

 

J

 

 

 

 

 

100mm (4")

 

 

 

 

 

 

K

 

 

 

 

 

150mm (6")

 

 

 

 

 

 

 

 

L

 

 

 

 

 

200mm (8")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Style

 

 

 

 

 

 

 

 

 

L

 

 

 

 

Detector/Converter combined type (LF410/LF600)

 

 

 

 

 

 

 

 

 

M

 

 

 

 

Detector/Converter separate type (LF410/LF602)

 

 

 

 

 

 

 

 

 

P

 

 

 

 

Detector/Converter combined type with PED (LF410/LF600) (Note 6)

 

 

 

 

 

 

 

 

 

Q

 

 

 

 

Detector/Converter separate type with PED (LF410/LF602) (Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM and CSA Class - I Division 2 type (Note 1)

 

 

 

 

 

 

 

 

 

A

 

 

 

 

Detector/Converter combined type (LF414/LF600)

 

 

 

 

 

 

 

 

 

B

 

 

 

 

Detector/Converter separate type (LF414/LF602)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection flange standard (Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

ANSI 150

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

ANSI 300

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

BS PN 10

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

BS PN 16

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

DIN PN 10

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

DIN PN 16

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

JIS 10K

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

JIS 16K

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

JIS 20K

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrode Material (Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

316L stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

Ti (titanium)

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

Pt-Ir (platinum/iridium)

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

Ta (tantalum)

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

Hastelloy C (Equivalent)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lining Material (Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

Alkali-resistant ceramic (Note 3)

 

 

 

 

 

 

 

 

 

 

 

 

B

 

Acid-resistant ceramic (Note 3)

 

 

 

 

 

 

 

 

 

 

 

 

C

 

Teflon PFA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grounding Ring Material (Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

316 stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

316L stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

Ti (titanium)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

Ta (tantalum)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

Pt-Ir (platinum/iridium)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Hastelloy C (Equivalent)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

other

 

 

Flow and calibration velocity range

A0.3 to 10 m/s (standard range calibration)

B0.3 to 10 m/s (specified range calibration)

C0.1 to 10 m/s (specified range calibration)

Excitation and Signal Cables

Anot provided

B30m cable, provided (Note 4)

Cother lengths, provided (Note 4)

Coating

 

 

A no coating

Bphthalic acid resin coating pearl-gray colored (Note 5)

Cblack tar epoxy resin 0.3 mm

Dblack tar epoxy resin 0.5 mm

EBlack tar epoxy resin 0.5 mm for submersible type (Note 7)

Size code explanation: :Object

: Standard

: Option

: Not available

Note1: Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter.

Note2: Same shape of flange standard among ANSI 150, ANSI 300, BS10, BS16, DIN10, DIN16, JIS10K, JIS16K, and JIS20K.

Note3: The type of material used is alumina ceramic, this is suitable for both acid and alkali liquids.

This ceramic lining and the electrodes are held with seals, there are two types, one for acids, and the other for alkalis. Note4: Separate type detector only. Specifyng the code “C”, indicate the length of cables from 1 to 300m in 1 meter increments. Note5: Phthalic acid resin coating is standard for the flowmeter with meter size 15mm(1/2”), 150mm(6”), and 200mm(8”). Note6: Consult Toshiba before ordering when choose materials at the wetting parts.

Note7: Ceramic lining only. (Teflon PFA lining is not available.)

Note8: Check the Table 2 whether your chosen meter size meets this directive or not when the meter is shipped to EU. If yes, need to choose this code.

14

Image 14
Contents Overall Specifications Measurement range in terms of flow velocityModel LF410 and LF414 Detectors Model LF600 and LF602 convertersCommunications output : HARTstd Digital output DO1 stdDigital output DO2 opt Cable connection ports Cable glands Vibration resistanceInstallation DimensionsSeparate type detectors LF410 and LF414 Meter size 15mm 1/2 Separate type detectors LF410 and LF414 Meter size 25mm External Connections Combined type LF410/LF600 and LF414/LF600 flowmetersSeparate type LF410/LF602 and LF414/LF602 flowmeters Wiring Precautions Wiring Precautions ProfibusPiping Precautions Grounding of the Combined type and Separate typeCalibration Range Meter SizeTo select the meter size PED matrix in each flange connectionOrdering Information About establishment environmentSpecification Code Wafer type detector LF410 Series Specification Code for converters ISO9001 and ISO14001 are certified