Toshiba LF410/LF602, LF410/LF600 specifications Specification Code for converters

Page 15

LF410/LF600 LF410/LF602

Table 4. Specification Code for converters

 

Model

 

 

Specification Code

Contents

LF600

LF602

1

2

3

4

5

6

7

8

9

10 11 12 13 14

 

type

type

L

F

6

0

 

 

 

 

 

 

Electromagnetic flowmeter converter

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

Integral (Combined) type

 

 

 

 

 

2

 

 

 

 

 

Separate (Remote) type

 

 

 

 

 

 

 

 

 

 

 

Purpose

 

 

 

 

 

 

 

A

 

 

 

 

Standard

 

 

 

 

 

 

 

F

 

 

 

 

cFMus class I, Division 2 approved

 

 

 

 

 

 

 

 

 

 

 

 

Shape

 

 

 

 

 

 

 

A

 

 

 

Integral type with case

 

 

 

 

 

 

B

 

 

 

Separate type with case

 

 

 

 

 

 

 

 

 

 

 

Converter mounting fitting

 

 

 

 

 

 

 

 

 

A

 

 

None

 

 

 

 

 

 

 

 

C

 

 

Panel, Accessory for wall mounting (BNP material: SUS304)

 

 

 

 

 

 

 

 

E

 

 

Accessory for pipe installation (BNP material: SUS304)

 

Digital input/output

1Digital output points 1 (DO1)

2Digital output points 2 (DO1+DO2) +Digital input point 1 (DI)

Current output and Communication function

1Current output + HART communication

2PROFIBUS communication (Current output is not usable)

Power supply

1100Vac-240Vac, 50/60Hz

224Vdc

3110Vdc

Instruction manual

AJapanese

E English

Code explanation:

: Standard

: Option –: Not available

15

Image 15
Contents Measurement range in terms of flow velocity Overall SpecificationsModel LF600 and LF602 converters Model LF410 and LF414 DetectorsDigital output DO1 std Digital output DO2 optCommunications output : HARTstd Vibration resistance Cable connection ports Cable glandsDimensions InstallationSeparate type detectors LF410 and LF414 Meter size 15mm 1/2 Separate type detectors LF410 and LF414 Meter size 25mm Combined type LF410/LF600 and LF414/LF600 flowmeters External ConnectionsSeparate type LF410/LF602 and LF414/LF602 flowmeters Wiring Precautions Profibus Wiring PrecautionsGrounding of the Combined type and Separate type Piping PrecautionsPED matrix in each flange connection Meter SizeTo select the meter size Calibration RangeAbout establishment environment Ordering InformationSpecification Code Wafer type detector LF410 Series Specification Code for converters ISO9001 and ISO14001 are certified