Toshiba LF410/LF600, LF410/LF602 Cable connection ports Cable glands, Vibration resistance

Page 4

LF410/LF600 LF410/LF602

Cable connection ports:

Cable glands

LF600 and LF602 without cFMus Approval: Provided as standard

OD of cableφ11~13mm Material Nylon 66

G (PF) 1/2 male screws.

Note: When PROFIBUS option is specified , cable grands size is φ6~8mm for signal cable, φ11~13mm for power cable.

LF600 and LF602 with cFMus Approval: Not provided, 1/2-14NPT male screws are required.

Applicable diameter — 11 to 13mm

(0.433 to 0.512 inch)

Vibration resistance:

No resonance to the following levels of vibration:

10 to 150Hz with acceleration of 9.8m/s2 No defect in putting vibration to each direction of 30Hz with 29.4 m/s2in 4h.

Note: Avoid using the flowmeter in an environment with constant vibration.

Converter LF602 dimensions and weights: See Figure 9 (for Separate type)

MTBF:220,000 hours at 25 deg.C (77 deg.F) based on MIL-HDBK-217F

4

Image 4
Contents Overall Specifications Measurement range in terms of flow velocityModel LF410 and LF414 Detectors Model LF600 and LF602 convertersDigital output DO2 opt Digital output DO1 stdCommunications output : HARTstd Cable connection ports Cable glands Vibration resistanceInstallation DimensionsSeparate type detectors LF410 and LF414 Meter size 15mm 1/2 Separate type detectors LF410 and LF414 Meter size 25mm External Connections Combined type LF410/LF600 and LF414/LF600 flowmetersSeparate type LF410/LF602 and LF414/LF602 flowmeters Wiring Precautions Wiring Precautions ProfibusPiping Precautions Grounding of the Combined type and Separate typeMeter Size To select the meter sizeCalibration Range PED matrix in each flange connectionOrdering Information About establishment environmentSpecification Code Wafer type detector LF410 Series Specification Code for converters ISO9001 and ISO14001 are certified