9. ANALOG SWEEP DISPLAY
The
DISP.
key switches
Simple weighing display
Except the UPPER & LOWER
Target weighing display LIMIT WEIGHT SETTING MODE
Limit check weighing display
Analog display OFF
It is possible to specify the display mode that will be shown first when the power is switched on. See the Function F16.
Use the analog sweep display with positive target and limit weights.
9-1. Selecting a display mode
Simple weighing display mode
The 60 segments represent zero to full scale. When the scale is in the net mode, the analog sweep display shows net weight.
In the TARGET WEIGHT SETTING MODE
The UPPER & LOWER LIMIT WEIGHT SETTING MODE
Target weighing display mode
The 60 segments represent zero to full scale. When the scale is in the net mode, the analog sweep display shows net weight.
In the TARGET WEIGHT SETTING MODE, the 40th segment will flash as the target weight. Thus the 60 segments represent the relative weight that the target weight is scaled to the 40 segments.
As the weight increases, the analog segments approach the flashing segment. This will provide a simple way of filling the container to the target weight.
The UPPER & LOWER LIMIT WEIGHT SETTING MODE
Limit check weighing display mode
The display shows comparison limits and results. The lower limit is shown at the 21st segment flashing and the upper limit is shown at the 40th segment flashing. The results will be known by the segments turned on.
19