CHAPTER 2. Ошибка! Стиль не определен.
|
|
| (continued) |
|
|
|
|
No | Code | Alarm Name | Definition |
|
| Minor Error | Minor Fault with Alarm Buffer saving |
64 | MNF01 | Card Out | A circuit card mounted in a universal slot has been re- |
|
|
| moved from service or is not recognized by the system. |
|
|
| Alarm Data = Cabinet, |
65 | MNF02 | Card In | A circuit card mounted in a universal slot has been re- |
|
|
| turned to service. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
66 | MNF03 | IPC Error | |
|
|
| Alarm Data = |
|
|
|
|
67 | MNF04 | Trunk Fault | Out of service trunk detected via loop detect. Internal |
|
|
| CODEC test. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
68 | MNF05 | Trunk Recovery | Out of service trunk detected via loop detected as out of |
|
|
| service is now operational. |
|
|
| Alarm Data = Cabinet, Slot, |
69 | MNF06 | Trunk Discon- | Out of service trunk detected via seizure of trunk. Exter- |
|
| nect | nal seizure test. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
70 | MNF07 | Trunk Connect | Out of service trunk recovered via seizure of trunk. Ex- |
|
|
| ternal seizure test. |
|
|
| Alarm Data = Cabinet, Slot, |
71 | MNF08 | SIO TxQ Over | SIO Tx Queue full error has occurred in the MCP2. |
|
|
| Alarm Data = SIO number(SIO: x) |
|
|
|
|
72 | MNF09 | SIO TxQ Under | SIO Tx Queue under error has occurred in the MCP2. |
|
|
| Alarm Data = SIO number(SIO: x) |
|
|
|
|
73 | MNF10 | E1 Out Of Srv | E1 Digital line status has been changed to out of ser- |
|
|
| vice. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
74 | MNF11 | E1 In Service | E1 Digital line has been restored to normal service. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
75 | MNF12 | SIO Out | IO port has lost DTR. |
|
|
| Alarm Data = SIO number(SIO: x) |
|
|
|
|
76 | MNF13 | SIO In | IO port has regained DTR. |
|
|
| Alarm Data = SIO 1 through 6 |
77 | MNF14 | TODC Error | Time of Day Clock in the MCP2 has erred. |
78 | MNF15 | TSW Over Alarm | The TSW has been requested to exceed the capacity of |
|
|
| available time slots. Maximum 192 per cabinet. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
79 | MNF16 | PSU Alarm | There are more ports than can be supported in a |
|
|
| cabinet and more power is required. |
|
|
| Alarm Data = Cabinet, |