Braun RA500 service manual Ramp Installation, Installation / Service Safety Precautions

Page 18

RAMP INSTALLATION

Safety Symbols

 

SAFETY FIRST! Know That....

 

 

 

 

 

 

 

 

 

 

 

 

 

All information contained

 

 

 

 

 

 

 

 

 

 

 

 

A

in this manual and

B

 

 

WARNING

 

 

C

 

 

CAUTION

 

 

supplements (if included), is pro-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This symbol indicates

 

 

 

 

 

This symbol indicates

 

vided for your safety. Familiarity

 

 

 

 

 

 

 

 

 

with proper operation instructions

 

 

 

important safety

 

 

 

 

 

important informa-

 

as well as proper maintenance

 

 

 

information regarding

 

 

 

 

 

tion regarding how to

 

procedures are necessary to en-

 

 

 

a potentially hazard-

 

 

 

 

 

avoid a hazard-

 

sure safe, trouble free operation.

 

 

 

ous situation that

 

 

 

 

 

ous situation that

 

Safety precautions are provided

 

 

 

could result in serious

 

 

 

 

 

could result in minor

 

to identify potentially hazardous

 

 

 

bodily injury and/or

 

 

 

 

 

personal injury or

 

situations and provide instruction

 

 

 

property damage.

 

 

 

 

 

property damage.

 

on how to avoid them.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D Note: Additional information provided to help clarify or detail a specific subject.

These symbols will appear throughout this manual. Recognize the seriousness of this information.

Installation / Service Safety Precautions

WARNING

If installation, main- tenance or repair procedures cannot be completed ex- actly as provided in this manual or if the instructions are not fully understood, contact The Braun Corporation immedi- ately. Failure to do so may result in serious bodily injury and/or property damage.

WARNING

CAUTION

WARNING

WARNING

WARNING

WARNING

WARNING

Read this manual and supplement(s) before performing instal- lation, operation or service procedures.

Installation specifications and dimensions must be met.

Remove any obstructions within the ramp mounting/operating area prior to beginning installation procedures.

Do not operate ramp prior to positive securement of the pan.

Check for obstructions such as gas lines, wires, exhaust, etc. before drilling or cutting during installation procedures.

Route all cables clear of exhaust system, other hot areas, moving parts, wet areas, etc.

Risk of electrical shock or fire! Use extra care when making electrical connections. Connect and secure as outlined in Installation Instructions and Wiring Diagrams.

WARNING Maintenance and repairs must be performed only by authorized service personnel.

WARNING Perform maintenance and lubrication procedures exactly as outlined in the Maintenance and Lubrication Schedule contained in this manual. Disconnect the power cable at the battery prior to servicing.

WARNING Keep hands, arms and all other body parts clear of moving parts.

Page 16

Image 18
Contents Braun Congratulations Contents Ramp Terminology Ramp Terminology IllustrationFigure B Ramp Components Terminology IllustrationIntroduction Ramp Components Pan Weldment HousingChain Drive Assembly Control Box Electronic ConRamp Operation Ramp Operation Ramp Access Doors and Interlocks Operation Notes and DetailsRead and become Operation safetyPrecautions, pre Familiar with all rampWeight Sensing Pad optional Ramp Power OperationOperator Input Switches Halt Conditions Several condi One-Touch Operation In oneVehicle to ac Provide adequateClearance outside Commodate rampProvided. Failure to re-engage Safety precautions Result in unintended rampRamp Manual Operation Become familiar with all ramp Secure the platform mayFigure D Ramp Passenger Safety Ramp Operation Ramp Installation Installation / Service Safety PrecautionsRamp Installation Read this manual Installation RequirementsInstallation, operation Before performingFigure F Floor Pocket Clear Opening Dimensions 1005mmClear Door Opening Width Dimension Figure HInstalled Ramp Stowed Figure JFigure K Figure L Figure M Installed Ramp Stowed RA500 w/o Fixed Sub floor Figure NFigure P Other hot areas Route cables clearExhaust system Moving parts. FailureInstaller-provided Positive + batteryLead wire must be Protected byMaintenance and Lubrication Lubrication DiagramMaintenance and Lubrication Introduction CyclesYear or 1250 Cycles Properly Electronic ControllerController only if ramp does not function Establish a connection between the computerSystems Descriptions Deploy Limit Stow Limit Adjust limits as followsLimit Adjustment Chart Operation Deploy MIN. Stow MAXManual Calibration Instructions for Controller PortImproper microswitch Adjustment mayIN-Limit Microswitch Manual Release Signal MicroswitchTroubleshooting Troubleshooting Diagnosis ChartDeploy Repair Parts Qty Description RA500-3236Detail a Exploded ViewWiring Schematic RampWiring Diagram Cond Wire CodeDaily Preventive Maintenance Schedule Pre-Trip InspectionProviding Access to the World Braun Commercial RA500 Transit Ramp