Braun RA500 service manual Systems Descriptions, Deploy Limit Stow Limit Adjust limits as follows

Page 36

SYSTEMS DESCRIPTIONS

Computer Calibration Instructions for Controller (continued)

Calibrate the Controller:

Press the “Calibrate” button on the controller (see Figure S). Ensure that the Calibrate LED is red. If connected properly, a text window will pop up. The numerical values will be different, but the general format of the text window will read similar to the fol- lowing:

Deploy Limit: 50

Stow Limit: 975

Adjust limits as follows:

 

Note: Use Limit Adjustment Chart to calculate the Deploy and Stow limit values. Three charts are provided on the right for calculation.

1.Ensure that the Calibrate LED is red.

2.Function the ramp through 4 complete deploy and stow cycles.

3.Record the Deploy Minimum and Stow Maxi- mum values.

4.Average the Deploy Minimum and Stow Maxi- mum values.

5.Subtract 10 from the Average Delpoy Minimum value.

6.Add 10 to the Average Stow Maximum value.

7.Adjust the stow limit and the deploy limit po- tentiometers to show values caluclated above. Values will display on computer screen as the potentiometers are adjusted.

Note: Clockwise rotation of potentiometers de- creases values.

Once the limits are set, return the ramp to nor- mal operation by pressing the “Calibrate” button a second time. Make sure that the Calibrate LED is changed to green.

Note: To reinstall factory default values, press the “Calibrate” button, followed by pressing the “Cali- brate Reset” button (see Figure S).

Limit Adjustment Chart:

Operation

Deploy MIN. Stow MAX.

Cycle 1 (C1)

 

 

Cycle 2 (C2)

 

 

Cycle 3 (C3)

 

 

Cycle 4 (C4)

 

 

Total (C1+C2+C3+C4)

 

 

Average (Total / 4)

 

 

Deploy Limit (Avg. - 10)

 

N/A

Stow Limit (Avg. + 10)

N/A

 

Operation

Deploy MIN. Stow MAX.

Cycle 1 (C1)

 

 

Cycle 2 (C2)

 

 

Cycle 3 (C3)

 

 

Cycle 4 (C4)

 

 

Total (C1+C2+C3+C4)

 

 

Average (Total / 4)

 

 

Deploy Limit (Avg. - 10)

 

N/A

Stow Limit (Avg. + 10)

N/A

 

Operation

Deploy MIN. Stow MAX.

Cycle 1 (C1)

 

 

Cycle 2 (C2)

 

 

Cycle 3 (C3)

 

 

Cycle 4 (C4)

 

 

Total (C1+C2+C3+C4)

 

 

Average (Total / 4)

 

 

Deploy Limit (Avg. - 10)

 

N/A

Stow Limit (Avg. + 10)

N/A

 

Page 34

Image 36
Contents Braun Congratulations Contents Ramp Terminology Ramp Terminology IllustrationFigure B Ramp Components Terminology IllustrationIntroduction Pan Weldment Housing Chain Drive AssemblyRamp Components Control Box Electronic ConRamp Operation Ramp Operation Ramp Access Doors and Interlocks Operation Notes and DetailsOperation safety Precautions, preRead and become Familiar with all rampRamp Power Operation Operator Input Switches Halt Conditions Several condiWeight Sensing Pad optional One-Touch Operation In oneProvide adequate Clearance outsideVehicle to ac Commodate rampSafety precautions Result in unintended ramp Ramp Manual OperationProvided. Failure to re-engage Become familiar with all ramp Secure the platform mayFigure D Ramp Passenger Safety Ramp Operation Ramp Installation Installation / Service Safety PrecautionsRamp Installation Installation Requirements Installation, operationRead this manual Before performingFigure F Floor Pocket Clear Opening Dimensions 1005mmClear Door Opening Width Dimension Figure HInstalled Ramp Stowed Figure JFigure K Figure L Figure M Installed Ramp Stowed RA500 w/o Fixed Sub floor Figure NFigure P Route cables clear Exhaust systemOther hot areas Moving parts. FailurePositive + battery Lead wire must beInstaller-provided Protected byMaintenance and Lubrication Lubrication DiagramMaintenance and Lubrication Introduction CyclesYear or 1250 Cycles Electronic Controller Controller only if ramp does not functionProperly Establish a connection between the computerDeploy Limit Stow Limit Adjust limits as follows Limit Adjustment ChartSystems Descriptions Operation Deploy MIN. Stow MAXManual Calibration Instructions for Controller PortImproper microswitch Adjustment mayIN-Limit Microswitch Manual Release Signal MicroswitchTroubleshooting Troubleshooting Diagnosis ChartDeploy Repair Parts Qty Description RA500-3236Detail a Exploded ViewWiring Schematic RampWiring Diagram Cond Wire CodeDaily Preventive Maintenance Schedule Pre-Trip InspectionProviding Access to the World Braun Commercial RA500 Transit Ramp