Braun RA500 service manual IN-Limit Microswitch, Manual Release Signal Microswitch

Page 39

IN-Limit Microswitch

The IN-Limit microswitch is located in the inboard mounting position of the platform carrier plate.

To adjust:

1.Power or manually move the ramp to the fully stowed position.

2.Remove the ramp top plate (cover).

3.With the ramp in the stowed position loosen the IN-Limit microswitch mounting screws.

4.Slide the switch body outward until resistance is felt from the switch being fully depressed.

5.Tighten the mounting screws in this position.

6.Replace the ramp top plate (cover), before oper- ating the ramp.

Manual Release Signal Microswitch

The MR-Signal microswitch is located behind the electric motor mounting plate.

To adjust:

1.Power or manually move the ramp to the fully stowed position.

2.Remove the ramp top plate (cover).

3.Disengage the manual release T-handle to so the ramp is in the manual release state.

4.Loosen the MR-Signal microswitch mounting screws.

5.Slide the switch body toward the motor mount- ing plate until resistance is felt from the switch being fully depressed.

6.Tighten the mounting screws in this position.

7.Re-engage the manual release T-handle.

8 . Replace the ramps top plate (cover), before operating the ramp.

SYSTEMS DESCRIPTIONS

IN-Limit

Microswitch

Figure M

Ramp in Fully-StowedPosition

(As viewed from under the carrier plate)

MR-Signal

Microswitch

Figure N

Ramp in Fully-StowedPosition

Page 37

Image 39
Contents Braun Congratulations Contents Ramp Terminology Illustration Ramp TerminologyRamp Components Terminology Illustration Figure BIntroduction Control Box Electronic Con Pan Weldment HousingChain Drive Assembly Ramp ComponentsRamp Operation Ramp Operation Operation Notes and Details Ramp Access Doors and InterlocksFamiliar with all ramp Operation safetyPrecautions, pre Read and becomeOne-Touch Operation In one Ramp Power OperationOperator Input Switches Halt Conditions Several condi Weight Sensing Pad optionalCommodate ramp Provide adequateClearance outside Vehicle to acBecome familiar with all ramp Secure the platform may Safety precautions Result in unintended rampRamp Manual Operation Provided. Failure to re-engageFigure D Ramp Passenger Safety Ramp Operation Installation / Service Safety Precautions Ramp InstallationRamp Installation Before performing Installation RequirementsInstallation, operation Read this manualFigure F 1005mm Floor Pocket Clear Opening DimensionsFigure H Clear Door Opening Width DimensionFigure J Installed Ramp StowedFigure K Figure L Figure M Figure N Installed Ramp Stowed RA500 w/o Fixed Sub floorFigure P Moving parts. Failure Route cables clearExhaust system Other hot areasProtected by Positive + batteryLead wire must be Installer-providedLubrication Diagram Maintenance and LubricationCycles Maintenance and Lubrication IntroductionYear or 1250 Cycles Establish a connection between the computer Electronic ControllerController only if ramp does not function ProperlyOperation Deploy MIN. Stow MAX Deploy Limit Stow Limit Adjust limits as followsLimit Adjustment Chart Systems DescriptionsPort Manual Calibration Instructions for ControllerAdjustment may Improper microswitchManual Release Signal Microswitch IN-Limit MicroswitchTroubleshooting Diagnosis Chart TroubleshootingDeploy Qty Description RA500-3236 Repair PartsExploded View Detail aRamp Wiring SchematicCond Wire Code Wiring DiagramPre-Trip Inspection Daily Preventive Maintenance ScheduleProviding Access to the World Braun Commercial RA500 Transit Ramp