Braun RA500 service manual Deploy

Page 41

 

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

FUNCTION

SYMPTOM

 

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

2.10

2.11

Pressure mat activated

Remove object from mat.

 

Ramp Starts

 

2.12

Obstruction sensing activated

See controller diagnostic guide

 

to Deploy

Check ramp for obstructions.

 

then Stops

 

 

Check ramp for excessive debris

 

 

 

 

contamination inside cassette

2.00

 

 

 

 

2.20

 

 

 

DEPLOY

Ratcheting

2.21

Ramp OUT-Limit microswitch is out

Check adjustment or replace

OPERATION

Noise at End

 

of adjustment or defective

 

 

or during

 

 

 

 

 

 

 

Ramp

 

 

 

 

Deployment

 

 

 

 

 

 

 

 

 

2.30

2.31

Loose chain

Adjust chain

 

Excessive

2.32

Debris inside ramp cassette

Clean debris from cassette

 

Noise during

 

 

 

 

Ramp

 

 

 

 

Deployment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.10

3.11

Pressure mat activated

Remove object from mat.

 

Ramp Starts

3.12

Obstruction sensing activated

See controller diagnostic guide

 

to Stow

Check ramp for obstructions.

 

then Stops

 

 

Check ramp for excessive debris

 

 

 

 

contamination inside cassette

3.00

 

 

 

 

3.20

 

 

 

STOW

 

 

 

Ratcheting

3.21

Ramp full in limit switch defective

Check adjustment or replace

OPERATION

Noise at End

 

 

 

 

or during

 

 

 

 

Ramp Stowing

 

 

 

 

 

 

 

 

 

3.30

3.31

Lose chain

Adjust chain

 

Excessive

 

Noise while

3.32

Debris inside ramp cassette

Clean debris from cassette

 

Ramp

 

 

 

 

Stowing

 

 

 

 

 

 

 

 

Page 39

Image 41
Contents Braun Congratulations Contents Ramp Terminology Illustration Ramp TerminologyRamp Components Terminology Illustration Figure BIntroduction Chain Drive Assembly Pan Weldment HousingRamp Components Control Box Electronic ConRamp Operation Ramp Operation Operation Notes and Details Ramp Access Doors and InterlocksPrecautions, pre Operation safetyRead and become Familiar with all rampOperator Input Switches Halt Conditions Several condi Ramp Power OperationWeight Sensing Pad optional One-Touch Operation In oneClearance outside Provide adequateVehicle to ac Commodate rampRamp Manual Operation Safety precautions Result in unintended rampProvided. Failure to re-engage Become familiar with all ramp Secure the platform mayFigure D Ramp Passenger Safety Ramp Operation Installation / Service Safety Precautions Ramp InstallationRamp Installation Installation, operation Installation RequirementsRead this manual Before performingFigure F 1005mm Floor Pocket Clear Opening DimensionsFigure H Clear Door Opening Width DimensionFigure J Installed Ramp StowedFigure K Figure L Figure M Figure N Installed Ramp Stowed RA500 w/o Fixed Sub floorFigure P Exhaust system Route cables clearOther hot areas Moving parts. FailureLead wire must be Positive + batteryInstaller-provided Protected byLubrication Diagram Maintenance and LubricationCycles Maintenance and Lubrication IntroductionYear or 1250 Cycles Controller only if ramp does not function Electronic ControllerProperly Establish a connection between the computerLimit Adjustment Chart Deploy Limit Stow Limit Adjust limits as followsSystems Descriptions Operation Deploy MIN. Stow MAXPort Manual Calibration Instructions for ControllerAdjustment may Improper microswitchManual Release Signal Microswitch IN-Limit MicroswitchTroubleshooting Diagnosis Chart TroubleshootingDeploy Qty Description RA500-3236 Repair PartsExploded View Detail aRamp Wiring SchematicCond Wire Code Wiring DiagramPre-Trip Inspection Daily Preventive Maintenance ScheduleProviding Access to the World Braun Commercial RA500 Transit Ramp