Barco MGD 221 MKII user manual Appendix a Background Information, Luminance Uniformity Correction

Page 33

APPENDIX A:

BACKGROUND INFORMATION

Luminance Uniformity Correction

A characteristic (or limitation) of every picture tube (CRT) is that the luminance decreases towards the edge of the screen surface. The decrease is normally 20 to 30 %.

This is caused by the shape of the picture tube. Inside the CRT, a so- called electron gun shoots an electron beam towards the front (the glass panel). Because this panel is rather flat instead of having a spheric shape, the electron beam has to 'travel' a longer distance in the corners than in the center. So the intensity is higher in the center.

This phenomenon is even increased by the irregular distribution of the phosphor and aluminium layer on the glass panel. These tend to be thicker in the center.

BARCO has developed a special system, called Luminance Uniformity Correction (LUC), that solves this problem. The LUC system enhances the light output at the edges of the CRT, so that the luminance there is the same as in the center.

The LUC system is calibrated in the factory. From time to time, it has to be re-calibrated at the customer's site by means of the light sensor you use for normal color calibration. The system can be calibrated and switched on or off by a qualified technician.

Power saving system

The display is equipped with circuits that can handle power saving management. When the system is switched on, it can power down the display in several steps.

The system is controlled by the imaging board or the PC that delivers the video signals. When you are working on the computer, the imaging board delivers both sync signals, and the display is operating normally. When you don't touch the computer keyboard for a certain time, the imaging board only delivers vertical sync. This is sensed by the display's micro controller, that blanks the image on the CRT. This results in a drop of power consumption with about 25 %.

Background information

34

Image 33
Contents Medical Greyscale Display MGD 221 MkiiTrademark information MGD 221 Users Guide Safety Instructions MGD 221 Users Guide Contents MGD 221 Users Guide Overview IntroductionPower saving system Versions and optionsAbout the manuals Installation PrecautionsPackage contents Controls and connectors Connection of video signals Signal connectionConnection of optical sensor Connection of data signalsPositioning the display Connection of powerImportant considerations Power on/off Switching on / offAutomatic power saving system Dpms Operation User ControlsContrast and brightness control To activate the OSDTo put contrast in calibrated position To control contrast manually To put brightness in calibrated positionTo control brightness manually Viewing Status information To view the status informationExplanation of the Status information menu items Activity timeout Other adjustmentsAdvanced Settings and Adjustments For Service Staff only SettingsTo change the settings Saving the settings Explanation of the Settings menu itemsHow to make the adjustments AdjustmentsDescription of the adjustments Geometry RotationAdvanced Interlacing Post correction Interlacing Pre correctionSH Compensation optional SH Compensation SH Compensation ON/OFFSH Compensation SH Position Advanced Advanced Focus Static focus To adjust the ALC system, proceed as followsFocus zone ALC optionalHow to save changes Proceed as follows Factory resetLuminance uniformity What happens upon saving?Maintenance Picture tubeCabinet Troubleshooting There appears no image, the green LED is onThere appears no image, the green LED is blinking Luminance Uniformity Correction Appendix a Background InformationPage AR panel 30% Appendix B Technical Specifications