Braun 403 dimensions Connect Interlocks, Adjust Platform Angle, Lift Pump Module, Shipped

Page 3

Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494

4

Connect Interlocks

5

Adjust Platform Angle

Vehicle and Lift Interlocks

The pump module is equipped with a lift interface 9-circuit con- nector (female socket). A mating 9-circuit connector (male plug) is supplied.

To meet minimum NHTSA requirements, connect to vehicle interlock harness as outlined below (Steps 1-5)

Optional Interlock Kits

Universal Interlock Kit 30940K is available for easy interface with vehicle OEM electronic signals.

Instrument Panel Display Kit 30938K provides an LED Panel Display that interfaces with Braun Universal Interlock Kit 30940K.

Detailed installation instructions are supplied with interlock kits.

Note: All Braun Corporation in- terlocks require a positive (+12V) Lift Stowed signal (Pin 7).

WARNING

Install and verify proper operation of all NHTSA mandated interlocks as specified. Failure to do so will result in a non-compliant installation and may result in serious bodily injury and/or property damage.

Adjustments to platform angle may be required if base plate wedges are used. See Figures I and J.

Angle A

equals

Angle B.

A

Wedges

B

Approximately

Lift

Pump

Module

PUMP MODULE

CONNECTOR - J21

9-COND WIRE CODE

NO. SIGNAL DEFINITION

1NOT USED

2NOT USED

3NOT USED

4NOT USED

5NOT USED

6VEHICLE SECURE (INPUT)

7LIFT STOWED (+12V)

8NOT USED

9LIFT STOWED (GND)

1 2 3

4 5 6

7 8 9

1 2 3

4 5 6

7 8 9

Figure H

INTERLOCK

CONNECTOR - P21

9-COND WIRE CODE

NO. SIGNAL DEFINITION

1NOT USED

2NOT USED

3NOT USED

4NOT USED

5NOT USED

6VEHICLE SECURE (INPUT)

7LIFT STOWED (+12V)

8NOT USED

9LIFT STOWED (GND)

3 2 1

6 5 4

9 8 7

3 2 1

6 5 4

9 8 7

1” Clearance

Inboard

Outboard

 

 

Figure I

 

H

 

G

T

 

E

I

T

 

N

2

Disconnect

As

Shipped

1 Disconnect and remove eye terminal

5

Connect

Note: Pins 7 and 9 300mA maximum.

3

Install 31798A

in cavity 7 (+) or 9 (-)

Floor Level Positioning:

Reset floor level positioning if wedges are used. See Floor Level Adjustment panel.

WARNING

Turn

clockwise

to

raise

outboard end

of platform

Reset floor level position as specified

 

T

 

o

 

Interlock

Manufacturer’s Part Numbers

4

Connect vehicle

Connector: AMP 172169

interlock signal wires

Terminal:TYCO 770904-3

 

(

LIFT

 

Y

SIGNALOWED

 

 

 

ellow/Light

VEHICLE

 

 

T

 

 

Blue)

SIGNAL

 

 

 

(Grey/Red)

SECURE

 

in Floor Level Adjustment Instruc- tions if wedges are used. Failure to do so may result in serious bodily injury and/or property damage.

 

OS

 

O

E

L

 

 

N

Figure J

Turn

counterclockwise

to

lower

outboard end

of platform

Image 3
Contents DOT Private Use Lift Nhtsa Vehicle Physical Requirements Position LiftAttach Power and Ground Cables Secure LiftChassis Shipped Adjust Platform AngleConnect Interlocks Lift Pump ModulePlatform Floor Level Adjustment Platform Floor Level Position AdjustmentFollowing operations must be functionally verified To Unload Passenger Lift Operating InstructionsTo Open Doors To Unfold Platform OutManual Operating Instructions LG Light Grease Maintenance and LubricationMaintenance and Lubrication Schedule Lubrication Diagram 750Level with platform lowered fully and roll stop Maintenance and Lubrication Schedule1500 4500