Technical Data
Technical Data
Fire-Ball 225 (3:1)
Fluid to air ratio | 3:1 | |
Cycles/gallon (cycles/liter) | 43.5 (11.4) | |
Fluid flow @80 cpm (gpm/lpm) | ....................... 1.84 (7.0) | |
Pumping distance guideline | up to 250 ft. (76.2 m) | |
Maximum fluid pressure | 540 psi (3.7 MPa, 37 bar) | |
Air motor effective diameter | 2.25 in. (57.2 mm) | |
Air operating range | ||
...................................................................... |
Approx. air consumption and fluid flow @100 psi air and 80 cpm..... 8.5 scfm @2.1 gpm (.241 m3/min @7.9 lpm)
Dry suction lift (feet of water) | ......................................23 | |
Wetted materials | steel, polyurethane, aluminum, | |
............................................................... | ||
Air inlet port size | 3/8 in. npt(f) | |
Fluid inlet port size | 1.5 in. npt(f) | |
Fluid outlet port size | 1/2 in. npt(f) |
Sound pressure (measured 1 meter from unit)... 77.8dB
Sound pressure (ISO | 85.6dB |
Fire-Ball 300 (5:1)
Fluid to air ratio |
| 5:1 | |
Cycles/gallon (cycles/liter) | 28.4 | (8.6) | |
Fluid flow @80 cpm (gpm/lpm) | ......................... 2.8 | (9.3) | |
Pumping distance guideline | up to 500 ft. (152.5 m) | ||
Maximum fluid pressure | 900 psi (6.2 MPa, 62 bar) | ||
Air motor effective diameter | 3.0 in. (76.2 mm) | ||
Air operating range | |||
...................................................................... |
Approx. air consumption and fluid flow @100 psi air and 80 cpm..... 8.5 scfm @2.1 gpm (.241 m3/min @7.9 lpm)
Dry suction lift (feet of water) | 26 |
Wetted materials | steel, polyurethane, aluminum, |
........................................................................... | |
Air inlet port size | 3/8 in. npt(f) |
Fluid inlet port size | 1.5 in. npt(f) |
Fluid outlet port size | 1/2 in. npt(f) |
Sound pressure (measured 1 meter from unit) ...77.8dB
Sound pressure (ISO | 85.6dB |
Fire-Ball 425 (10:1)
Fluid to air ratio | 10:1 | |
Cycles/gallon (cycles/liter) | .............................. | 19.6 (5.2) |
Fluid flow @80 cpm (gpm/lpm) | 4.1 (15.4) | |
Pumping distance guideline | up to 750 ft. (228.6 m) | |
Maximum fluid pressure... | 1800 psi (12.4 MPa, 124 bar) | |
Air motor effective diameter | 4.25 in. (107.9 mm) | |
Air operating range | ||
...................................................................... |
Approx. air consumption and fluid flow @100 psi air and 80 cpm .32.0 scfm @4.1 gpm (.555 m3/min @15.4 lpm)
Dry suction lift (feet of water) | 26 |
Wetted materials ..steel, polyurethane, aluminum, nitrile
Air inlet port size | 1/2 in. npt(f) |
Fluid inlet port size | 1.5 in. npt(f) |
Fluid outlet port size | 3/4 in. npt(f) |
Sound pressure (measured 1 meter from unit) .80.85dB
Sound pressure (ISO | 94.62dB |
30 | Installation and Operation |