Graco 225 important safety instructions Mounting the Pump, Grounding

Page 7

Mounting the Pump

WARNING

Mount the pump securely so that it cannot move dur- ing operation. Failure to do so could result in personal injury or equipment damage.

Select a location that allows the operator easy access to the pump and air controls, sufficient room to change supply containers, and a secure mount- ing platform.

If you are mounting the pump directly on the supply container, be sure it is positioned so the pump’s intake tube is no more than 1 in. (25 mm) from the bottom of the container. Mount the pump to the cover or other suitable mounting device.

To prevent damage to the pump, remove sedi- ment from the bottom of the container before installing a pump in an existing container.

Grounding

Proper grounding is essential to maintaining a safe sys- tem.

To reduce the risk of static sparking, ground the pump. Check local electrical codes for detailed grounding instructions for your area and equipment type. Be sure the following equipment is properly grounded:

Pump: See FIG. 2

Air and Fluid hoses: Use only electrically conductive hoses.

Air compressor: Follow manufacturer’s recommen- dations.

Dispensing valve: Obtain grounding through con- nection to a properly grounded fluid hose and pump.

Fluid supply container: Follow your local code.

Object being lubricated: Follow your local code.

Any pails used when flushing: Use only metal, grounded pails when flushing. Make firm metal-to-metal contact between a metal part of the dispensing valve and the pail. Use the lowest possi- ble pressure.

Installation

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the dispensing valve firmly to the side of a metal pail and then open the dispensing valve.

To maintain grounding continuity when flushing or reliev- ing pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of ground wire, (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See FIG. 2. To order a ground wire and clamp order Part No. 222011.

Y

Z

TI1052

FIG. 2

Installation and Operation

7

Image 7
Contents Fire-Ball 225, 300, and 425 Oil Pumps Contents Fire-Ball 425 Packages PackagesModel Hose Cover/Bung Dispense Air Fire-Ball 300 Packages Manual Conventions Skin Injection Hazard Installation Grounding Mounting the PumpInstallation Installation Installation Installation Installation Mobil Mounting Layout Mobil MountingClosed Bung-Type-Drum Sturdi-Clamp-Mounted Pumps Operation Starting and Adjusting the PumpRelieving Pressure Parts Part No. Description Qty Parts ListParts Dispense KIT Part No. DescriptionParts Includes items 2a-2d 220591 Parts No. Part No. Description Parts For 246907, 225640 Includes items 2a-2d 222066 Drum Cover 207361 12c STURDI-CLAMP Fire-Ball 300 Fire-Ball 225Fire-Ball 425 Fire-Ball DimensionsGal lb drum size, cover mount Overall Length 45.6 in .8 cm Model 36.6 in .9 cm Graco Standard Warranty