Graco 225 important safety instructions Installation

Page 8

Universal Pump

Fire-Ball 225 Model 248230

Fire-Ball 300 Model 225852

Fire-Ball 425 Model 225853

1.Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the pump air inlet (D).

F

Installation

2.Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).

3.Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).

4.Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).

2d

D N

2b

2a

2c

FIG. 3

8

Installation and Operation

Image 8
Contents Fire-Ball 225, 300, and 425 Oil Pumps Contents Packages Model Hose Cover/Bung Dispense AirFire-Ball 300 Packages Fire-Ball 425 PackagesManual Conventions Skin Injection Hazard Installation Mounting the Pump GroundingInstallation Installation Installation Installation Installation Mobil Mounting Mobil Mounting LayoutClosed Bung-Type-Drum Sturdi-Clamp-Mounted Pumps Relieving Pressure Starting and Adjusting the PumpOperation Parts Parts List Part No. Description QtyParts Part No. Description Dispense KITParts Includes items 2a-2d 220591 Parts No. Part No. Description Parts For 246907, 225640 Includes items 2a-2d 222066 Drum Cover 207361 12c STURDI-CLAMP Fire-Ball 425 Fire-Ball 225Fire-Ball 300 Dimensions Fire-BallGal lb drum size, cover mount Overall Length 45.6 in .8 cm Model 36.6 in .9 cm Graco Standard Warranty