Chapter 3 Building the Network
3.10.1 Synchronization Settings for the ONS 15310, ONS 15327, ONS 15454 SONET, and ONS 15600 SONET
Table | SSM Generation 2 Message Set | |
|
|
|
Message | Quality | Description |
|
|
|
PRS | 1 | Primary reference |
|
|
|
STU | 2 | Sync traceability unknown |
|
|
|
ST2 | 3 | Stratum 2 |
|
|
|
TNC | 4 | Transit node clock |
|
|
|
ST3E | 5 | Stratum 3E |
|
|
|
ST3 | 6 | Stratum 3 |
|
|
|
SMC | 7 | SONET minimum clock |
|
|
|
ST4 | 8 | Stratum 4 |
|
|
|
DUS | 9 | Do not use for timing synchronization |
|
|
|
RES | — | Reserved; quality level set by user |
|
|
|
Note Alarms relating to PM collection indicate that the load on the system is high. Reduce the load on the system before proceeding.
3.10.1.1 Setting Up External or Line Timing for CTC-Based SONET NEs
Step 1 Select an ONS 15310, ONS 15327, ONS 15454 SONET, or ONS 15600 SONET NE and choose Configuration > NE Explorer.
Step 2 In the node property pane, click the Timing tab. Fields shown depend on the NE that is selected.
Step 3 In the General Timing section of the General subtab, complete the following information:
•Timing
Caution Because mixed timing can cause timing loops, Cisco does not recommend its use. Use this mode with care.
Note The Mixed option is not applicable to the ONS 15600 SONET.
•SSM Message
•
•Reversion
Cisco Transport Manager Release 6.0 User Guide
| ||
|