Chapter 3 Building the Network
3.10.2 Synchronization Settings for the ONS 15454 SDH and ONS 15600 SDH
Note Refer to the Cisco ONS 15454 SDH Troubleshooting Guide or Cisco ONS 15600 SDH
Troubleshooting Guide for
3.10.2.2 Setting Up Internal Timing for CTC-Based SDH NEs
If no BITS source is available, you can set up internal timing by timing all nodes in the ring from the internal clock of one node.
Caution Internal timing is Stratum 3 and not intended for permanent use. All nodes should be timed to a Stratum 2 or better primary reference source.
Step 1 Select an ONS 15454 SDH or ONS 15600 SDH NE and choose Configuration > NE Explorer.
Step 2 In the node property pane, select the Timing tab.
Step 3 In the General Timing section of the General subtab, enter the following information:
•Timing
•
•Reversion
Step 4 In the BITS Facilities section of the General subtab, enter the following information:
•E1, T1, 2.048 MHz, 64
•In State— Set BITS 1 and BITS 2 to OOS.
•Out State— Set BITS 1 and BITS 2 to OOS.
• State (Applicable to the ONS 15600
•
•
•Sync
•AIS
•
•Sa
Step 5 In the Reference List subtab, enter the following information:
| • | NE References |
|
|
|
|
| |
|
| – | Internal Clock. | |||||
|
| – | Internal Clock. | |||||
|
| – | Internal Clock. | |||||
| • | BITS 1 Out/BITS 2 Out (Applicable to the ONS 1545 | ||||||
|
|
|
| Cisco Transport Manager Release 6.0 User Guide |
|
| ||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
|
|