Braun Series A5 service manual 1500

Page 17

Maintenance and Lubrication Schedule

 

 

 

 

 

 

 

 

 

continued

 

 

Inspect microswitches for securement.

Resecure or replace if needed.

 

 

 

 

Make sure lift operates smoothly

Realign towers and vertical arms. Lubri-

 

 

 

 

 

 

cate or correct as needed.

 

 

 

 

Inspect external snap rings:

Resecure or replace if needed.

 

 

 

 

Lower fold arms (6)

 

 

 

 

 

 

Inner roll stop lever bracket pins (2)

 

 

 

 

 

 

Lift-Titelatch gas (dampening) springs (4)

 

 

 

 

 

 

Gear link assembly (4)

 

 

 

 

 

 

Lift-TiteLatch (2)

 

 

 

 

 

 

Vertical channel/platform link (2)

 

 

1500

 

 

Upper fold arm cam followers (4)

 

 

 

 

Outer barrier pins (2)

 

 

 

Cycles

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect inner roll stop locks and torsion springs for

Replace damaged parts. Apply Light Oil to

 

 

 

 

wear or damage and for proper operation.

inner roll stop lock pivot points.

 

 

 

 

Inspect platform fold axles for wear or damage and

Replace damaged parts and resecure as

 

 

 

 

positive securement

needed.

 

 

 

 

Inspect platform fold link rollers and bearings for

Resecure, replace or correct as needed.

 

 

 

 

wear or damage and positive securement

Note: Apply Loctite® to threads if needed.

 

 

 

 

Remove pump module cover and inspect:

Resecure, replace or correct as needed.

 

 

 

 

Hydraulic hoses, fittings and connections for

 

 

 

 

 

 

 

wear or leaks

 

 

 

 

 

 

Harness cables, wires, terminals and connec-

 

 

 

 

 

 

 

tions for securement or damage

 

 

 

 

 

 

Control board, circuit breaker, power switch and

 

 

 

 

 

 

 

lights for securement or damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Perform all procedures listed in previous section also

 

 

 

 

 

 

Inspect cotter pins on platform pivot pins (2)

Resecure, replace or correct as needed

 

 

 

 

Hydraulic Fluid (Pump) - Check level. Note: Fluid

Use Braun 32840-QT (Exxon® Univis HVI 26)

 

 

 

 

should be changed if there is visible contamination.

hydraulic fluid (do not mix with Dextron III or other

 

 

 

 

Inspect the hydraulic system (cylinder, hoses, fit-

hydraulic fluids). Check fluid level with platform

 

 

 

 

tings, seals, etc.) for leaks if fluid level is low.

lowered fully and roll stop unfolded fully. Fill

 

 

 

 

 

 

to within 1/2” of the bottom of the 1-1/2” fill tube

4500

 

 

 

 

(neck).

 

 

 

 

 

 

 

Cycles

 

Inspect cylinders, fittings and hydraulic connections

Tighten, repair or replace if needed.

 

 

 

 

for wear, damage or leaks

 

 

 

 

 

 

Inspect parallel arms, bushings and pivot pins for

Replace if needed.

 

 

 

 

visible wear or damage

 

 

 

 

 

 

Inspect parallel arm pivot pin mounting bolts (8)

Tighten or replace if needed.

 

 

 

 

Inspect vertical arms, handrails and pivot pins for

Replace damaged parts and lubricate if needed

 

 

 

 

visible wear or damage

 

 

 

 

 

 

Inspect upper/lower fold arms, saddle, saddle sup-

Replace if needed.

 

 

 

 

port and associated pivot pins, bushings, and bear-

 

 

 

 

 

 

ings for visible wear or damage

 

 

 

 

 

 

Inspect gas springs (cylinders - 4) for wear or dam-

Tighten, replace or correct as needed

 

 

 

 

age, proper operation and positive securement

 

 

 

continued

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 15

Image 17
Contents CKA Congratulations Warranty and Registration InstructionsContents Lift Terminology Switch and Sensor Locations Certification Checklist Diagnostic Procedures Platform Fold Pressure Adjustment Century NCL Series Vista NVL Series Platform Angle AdjustmentMillennium NL Series Platform Stop Blocks Platform Floor Level Adjustment Adjustment Guidelines Bridging Microswitch AdjustmentBridging Microswitch LCD Lift Codes Troubleshooting ProceduresFlashing Numbers Non-Flashing NumbersLubrication Diagram Maintenance and LubricationCycles Maintenance and Lubrication Schedule1500 Cycles 1500 Consecutive 750Cycle Intervals Lift Electrical Schematic Unfold Lift Wiring DiagramDescription Symbol Hydraulic SchematicQty Description Hydraulics Parts ListHydraulics Diagram Part Numbers of Items Dedicated per Lift Model Pump Module Parts ListPump Mounting Bolts Pump Module DiagramRepair Parts List Exploded View This page intentionally left blank Providing Access to the World CKA