The following operations and conditions must be functionally verified in order for the lift to be FMVSS 403/404 compliant. If an operation does not function as described or a condition is not met, follow the refer- enced procedures to correct the problem or contact a Braun Corporation Product Support representative at 1-800-THE LIFT®.

Vehicle movement is prevented unless the lift door is closed, ensuring the lift is stowed.

1.Verify on the pump module mounted interlock connector that the lift not stowed signal (pin 5) has an open signal - OR - lift stowed signal (pin 7) has a +12 volt signal - OR - (pin 9) has a ground signal (depends on interlock used).

2.Refer to the interlock installation instructions.

Lift operation shall be prevented unless the vehicle is stopped and vehicle movement is prevented.

1.Verify vehicle secure signal (pin 6) has a +12 volt signal.

2.Refer to the interlock installation instructions.

The platform will not fold/stow if occupied.

-Refer to Platform Fold Pressure Adjustment procedures.

The inner roll stop will not raise if occupied.

-Call Product Support

The outer barrier will not raise if occupied.

-Call Product Support

Verify platform lighting when lift is deployed and pendant illumination when lift is powered.

1.Replace bulb(s) in the light housing.

2.Check fuse (5 amp fuse on circuit board; F13)

A visual and audible warning will activate if the threshold area is occupied when the platform is at least 1" below floor level.

1.Remove the threshold warning plate

2.Verify the threshold strip switch connectors are connected

3.Replace the threshold strip switch

4.Reinstall the threshold warning plate

Platform movement is prohibited beyond the position where the inner roll stop is fully deployed (up).

-Call Product Support.

Lift platform movement shall be interrupted unless the outer barrier is deployed (up).

-Call Product Support.

Page 4

Image 6
Contents CKA Warranty and Registration Instructions CongratulationsContents Lift Terminology Switch and Sensor Locations Certification Checklist Diagnostic Procedures Platform Fold Pressure Adjustment Platform Angle Adjustment Millennium NL SeriesCentury NCL Series Vista NVL Series Platform Stop Blocks Platform Floor Level Adjustment Bridging Microswitch Adjustment Bridging MicroswitchAdjustment Guidelines Troubleshooting Procedures LCD Lift CodesNon-Flashing Numbers Flashing NumbersMaintenance and Lubrication Lubrication DiagramMaintenance and Lubrication Schedule Cycles1500 Cycles 1500 Consecutive 750Cycle Intervals Lift Electrical Schematic Lift Wiring Diagram UnfoldHydraulic Schematic Description SymbolHydraulics Parts List Qty DescriptionHydraulics Diagram Pump Module Parts List Part Numbers of Items Dedicated per Lift ModelPump Module Diagram Pump Mounting BoltsRepair Parts List Exploded View This page intentionally left blank Providing Access to the World CKA